mITX-BDW-U – User Guide, Rev. 1.6
www.kontron.com
// 39
Feature Connector Pinout
Note
Pull
U/D
Ioh/
Iol
Type
Signal
PIN
Signal
Type
Ioh/
Iol
Pull
U/D
Note
1
1M/
I
CASE_OPEN#
1
2
SMBC
/4 mA
10K/
25 mA
/25 mA
O
S5#
3
4
SMBD
/4 mA
10K/
25 mA
/25 mA
O
PWR_OK
5
6
EXT_BAT
PWR
I
TOUCH_RST#
7
8
TOUCH_INTR#
O
PWR
SB3V3
9
10
SB5V
PWR
IOT
GPIO0
11
12
GPIO1
IOT
IOT
GPIO2
13
14
GPIO3
IOT
IOT
GPIO4
15
16
GPIO5
IOT
IOT
GPIO6
17
18
GPIO7
IOT
PWR
GND
19
20
GND
PWR
I
GPIO8
21
22
GPIO9
I
I
GPIO10
23
24
GPIO11
I
I
GPIO12
25
26
GPIO13
IOT
IOT
GPIO14
27
28
GPIO15
IOT
IOT
GPIO16
29
30
GPIO17
IOT
PWR
GND
31
32
GND
PWR
8/8 mA O
EGCLK
33
34
EGCS#
O
8/8 mA
8/8 mA
EGAD
35
36
TMA0
O
PWR
+12 V
37
38
GND
PWR
2
1K/
I
TOUCH_I2C_C
LK
39
40
TOUCH_I2C_D
AT
I/O
1K/
2
PWR
GND
41
42
GND
PWR
PWR
GND
43
44 S3#
O
25 mA
/25mA
1) Pull-up to on-board Battery.
2) Pull-up to SB3V3.
Signal
Description
CASE_OPEN#
CASE OPEN, used to detect if the system case has been opened. This signal’s status is readable,
so it may be used like a GPI when the Intruder switch is not required.
SMBC
SMBus Clock signal
SMBD
SMBus Data signal
S3#
S3 sleep mode, active low output, optionally used to deactivate external system.
S5#
S5 sleep mode, active low output, optionally used to deactivate external system.
PWR_OK
Power OK, signal is high if no power failures are detected. (This is not the same as the P_OK
signal generated by ATX PSU).
EXT_BAT
(External Battery) option for conn terminal of an external primary cell battery (2.5 V -
3.47 V) (– terminal connected to GND). The external battery is protected against charging and
can be used with/without the on-board battery installed.
SB3V3
Max. load is 0.75 A (1.5 A < 1 sec.)
SB5 V
S5 V supply.
TOUCH_I2C_DAT
Serial I/O – I2 C interface data Line
TOUCH_I2C_CLK
Serial I/O – I2 C interface clock Line
TOUCH_RST#
Serial I/O –interface reset
TOUCH_INTR#
Serial I/O –interrupt line
GPIO0..17
General Purpose Inputs / Output. These Signals may be controlled or monitored through the use
of the KT-API-V2 (Application Programming Interface).
Summary of Contents for mITX-BDW-U
Page 1: ... USER GUIDE mITX BDW U User Guide Rev 1 6 Doc ID 1060 4825 KTD N0XXX A ...
Page 17: ...mITX BDW U User Guide Rev 1 6 www kontron com 17 3 2 mITX BDW U Block Diagram ...
Page 46: ...mITX BDW U User Guide Rev 1 6 www kontron com 46 System Information ...
Page 52: ...mITX BDW U User Guide Rev 1 6 www kontron com 52 Silicon Information ACPI Configuration ...
Page 99: ...mITX BDW U User Guide Rev 1 6 www kontron com 99 10 4 Boot ...
Page 102: ...mITX BDW U User Guide Rev 1 6 www kontron com 102 ...