KBox A-103 – User Guide, Rev. 3.0
// 41
5.1.3.
Serial Port COM 3 (X206) Configuration of the Serial Port COM 3
In order to configure the serial port COM3 as RS422 or RS485, there are following options to set the jumper J46
(Figure 23, pos. 3):
OPEN: RS485 half duplex (2 wires)
CLOSE: RS485 full duplex (4 wires) or
CLOSE: RS422 full duplex (8 wires) depends on user cabling connection to X206
Table 4: J46 settings forCOM 3 RS485 and RS422 modes (factory settings are in bold letters)
Communication Mode
COM 3 (X206)
Jumper J46
J44, onboard Header or COM 3
X206: DSUB (9-pin female)
RS485 half duplex
OPEN
Pin 1: TxD-/RxD-
Pin 5: TxD+/RxD+
Refer to pin assignment:
11.1.12
RS485 full duplex
CLOSE
Pin 1: TxD-
Pin 3: RxD+
Pin 5: TxD+
Pin 7: RxD-
Refer to pin assignment:
11.1.11
RS422 full duplex
CLOSE
Pin 1: TxD-
Pin 2: RTS-
Pin 3: RxD+
Pin 4: RTS+
Pin 5: TxD+
Pin 6: CTS+
Pin 7: RxD-
Pin 8: CTS-
Refer to pin assignment:
11.1.13
In the “Advanced
Kontron Board
RS422/485 DUPLEX Mode” menu of the BIOS setup,
“Half Duplex” or “Full Duplex” must be selected according to the selected communication
mode.