![Kontron CP6006-SA User Manual Download Page 80](http://html1.mh-extra.com/html/kontron/cp6006-sa/cp6006-sa_user-manual_1996551080.webp)
CP6006-SA – User Guide, Rev. 0.5 Preliminary
// 80
8.5.3.
Set Control State (SPI Boot Flash Selection, Boot Order Selection)
Table 55: Set Control State
COMMAND
LUN
NetFn
CMD
Set Control State (SPI Boot Flash, Boot Order)
00h
OEM = 3Eh
20h
REQUEST DATA
Byte
Data Field
1
Control ID:
00h = SPI boot flash selection
9Dh = uEFI BIOS boot order configuration
2
Control state for SPI boot flash selection (00h):
00h = Standard SPI boot flash is selected (default)
01h = Recovery SPI boot flash is selected
Note: The DIP switch SW1, switch 2, may overwrite the above selection.
Control state for uEFI BIOS boot order configuration (9Dh):
00h = Boot order is according to uEFI BIOS setup (default)
01h = Next boot device is: Floppy
02h = Next boot device is: HDD
03h = Next boot device is: CD
04h = Next boot device is: Network
05h = Next boot device is: USB Floppy
06h = Next boot device is: USB HDD
07h = Next boot device is: USB CD-ROM
RESPONSE DATA
Byte
Data Field
1
Completion code
The settings mentioned above are stored in EEPROM and applied (to logic) each time the
IPMI controller detects power-on.