konner-sohnen.com
|
6
SPECIFICATIONS
3
To ensure reliability and increase the engine service life, peak powers may be slightly limited by circuit
breakers.
The optimal operating conditions are ambient temperature of 17-25°C, barometric pressure of 0.1 MPa
(760 mm Hg), and relative humidity of 50-60%. Under these environmental conditions, the generator can
provide maximum performance in terms of the declared specifications.
In the event of deviations from these environmental indicators, the generator performance may vary.
Please note that continuous loads exceeding 80% of the generator’s rated power are not recommended in
order to extend its service life.
*LPG operation reduces generator power by 10%.
**Fuel consumption depends on many factors, such as load, fuel quality, season, altitude, technical con
-
dition of the generator.
Model
KS 2000i S
KS 2000iG S
Voltage, V
230
Maximum power, kW
2.0
2.0*
Nominal power, kW
1.8
1.8*
Frequency, Hz
50
Current, A (max.)
8.7
8.7
Outlets
1*16A
1*16A
Engine start
manual
manual
Fuel tank volume, l
5
5
Working time at 50% load
(gasoline fuel)**, h
6.25
6.25
LED display
voltage, frequency, working hours
Noise level Lpa (7m)/Lwa, dB
62/87
62/87
Output 12V, A
-
-
USB-Outputs
5V/1A, 5V/2.1A
-
Engine model
KS 100i
KS 100i
Engine volume, cm
3
79.7
79.7
Engine type
gasoline, 4 stroke cycle engine
LPG/gasoline 4 stroke cycle engine
Engine power, hp
2.5
2.5
Generator parallel socket
+
+
Crankcase volume, l
0,4
0,4
Power factor, cos φ
1
1
ATS input
-
-
Dimensions (LxWxH), mm
555х335х540
700х335х540
Lithium battery, Ah
-
-
Net weight, kg
19
19
Protection class
IP23M
Nominal voltage tolerance – max. 5%
Summary of Contents for KS 2000i S
Page 23: ......