1. Close the gas valve on the cylinder.

2. Open the vent on the fuel cap to the “ON”

3. 

Set the fuel switch to “ON” and close the air choke on the control panel (for model KS 2000iG S).

4. Start the engine by hand or electric start.

5. Open the air choke  (for model KS 2000iG S).

For all modifications of models KS 2000i, loosen the 4 

screws on the side panel. Loosen drain screw 

C

 on the 

carburetor and let the remaining fuel drain through pipe 

D

 into the dedicated drip pan. Avoid gasoline leaks. 

Tighten up the screw. Install back the generator housing 

cover. Start the generator on LPG. 

To drain gasoline from the carburetor, turn off the fuel valve and wait until the generator has cooled down 

sufficiently. For open frame models, place a drip pan under the carburetor and loosen the drain screw on 

the carburetor (Fig. 5). Make sure that no fuel leaks onto the generator. Tighten up the screw again. Start 

the generator on LPG according to the instructions mentioned above

Disconnect the load from the generator before changing 

fuel. The ECONOMY MODE switch must be in the “OFF” 

position. 

IMPORTANT!

For model KS 2000iG S: It is recommended to stop the generator before switching from 

gasoline to LPG! Gasoline remains in the carburetor make it difficult to start the engine 

on LPG. Let the generator run out of gasoline until it stops. To do this, close the fuel valve 

with the generator running and wait until the generator stops completely. Then start the 

generator on LPG. You can also drain the remaining gasoline from the carburetor before 

starting the generator on LPG.

RUNNING GENERATOR ON LPG (KS 4100iEG, KS 8100iEG ATSR, 

RUNNING GENERATOR ON LPG (KS 4100iEG, KS 8100iEG ATSR, 

KS 8100iEG, 

KS 8100iEG, KS 2000iG S,  

KS 2000iG S,  

KS 4000iEG S)

KS 4000iEG S)

С

KS 2000iG S

D

4. Connect the hose end with the reducer to the gas cylinder (connect hose end 

B

 to the gas cylinder, as 

shown in Fig. 4).

5. Open the gas valve on the cylinder, making sure that no gas is leaking.
6. Press the pressure relief valve on the reducer 2-3 times (see Fig. 4). 
7. Turn the Multifunctional engine switch to the “START” position.

8. For manual start, pull the manual starter until a slight resistance is felt, then pull it toward you relatively 

sharply. Slowly turn the manual starter by hand, do not release it abruptly. For electric start, press the red 

button on the multifunctional engine switch (fig. 1)
9. After starting the engine, turn the Multifunctional engine switch to the “RUN” position (fig. 1).
10. When using for the first time, fill the gas line with gas by turning the key (pressing start button) to the 

“OFF” position and slowly pull the starter handle to the full cord length 2 to 3 times (except for models 

KS 8100, which do not have a manual start). 

For model KS 2000iG S:

 Close the air choke (pull the air choke handle) if the generator is not warmed 

up. 

Set the GASOLINE FUEL SWITCH to the “OFF” position, set the engine start to the “ON” position,

 grasp 

the starter handle and slowly pull it until resistance is felt. Pull the starter cord to the full length with a sharp 

movement. The generator will start. If this is not the case, repeat this action. Slowly turn the manual starter 

by hand, do not release it abruptly. 

Open the air choke by pushing the air choke handle.

Place the container with gas only vertically, according to 

the instruction manual for gas cylinders. The horizontal 

placement of gas cylinders leads to hybrid generator 

gearbox failure.

IMPORTANT!

konner-sohnen.com

   

|

    15

Summary of Contents for KS 2000i S

Page 1: ...E KS 8100iEG KS 8100iE ATSR KS 8100iEG ATSR Inverter Generator Inverter Generator in Soundproof Housing EN Please read this manual carefully before use KS 2000i S KS 2000iG S KS 4000iE S KS 4000iEG S...

Page 2: ...f the generator Keep unauthorized persons children and animals away from work area Wear safety shoes and gloves We care about the environment therefore we consider it expedient to save We care about t...

Page 3: ...r must not be paralleled with other pow er sources The generator must not be used in parallel with on grid inverters even if allowed in the operating instructions for the inverter ATTENTION DANGER Usi...

Page 4: ...uefied gas is forbidden When you operate using gasoline you must stop LPG supply When you operate generator using LPG you must stop gasoline supply ATTENTION DANGER MAIN OVERVIEW 2 MODELS KS 4100 MODE...

Page 5: ...ver on the other side of the generator 3 4 5 6 1 2 1 2 USB Outputs 2 Economy mode switch C N 3 LED display 4 12V DC fuse 5 2x16 AC outlets 6 Earthing bolt 7 Generator parallel socket 8 Reset button 9...

Page 6: ...S 2000iG S konner sohnen com 5 In addition to the components shown in the figure of a gasoline generator a generator with a hybrid system LPG gasoline is equipped with a hose for supplying LPG to the...

Page 7: ...er by 10 Fuel consumption depends on many factors such as load fuel quality season altitude technical con dition of the generator Model KS 2000i S KS 2000iG S Voltage V 230 Maximum power kW 2 0 2 0 No...

Page 8: ...ge frequency working hours overload indicator voltage indicator oil level indicator Model KS 4000iE S KS 4000iEG S KS 4000iE S ATS Voltage V 230 Maximum power kW 4 0 4 0 4 0 Nominal power kW 3 5 3 5 3...

Page 9: ...rotection class IP23M Nominal voltage tolerance max 5 To ensure reliability and increase the engine service life peak powers may be slightly limited by circuit breakers The optimal operating condition...

Page 10: ...425 685 420 430 Lithium battery Ah 1 6 1 6 Net weight kg 36 7 38 Protection class IP23M Nominal voltage tolerance max 5 To ensure reliability and increase the engine service life peak powers may be sl...

Page 11: ...t Crankcase volume l 1 1 1 1 1 1 1 1 Power factor cos 1 1 1 1 ATS input Dimensions LxWxH mm 725 505 555 765 505 555 725 505 555 765 505 555 Lithium battery Ah 1 6 1 6 1 6 1 6 Net weight kg 65 8 68 68...

Page 12: ...NERATOR OPERATION 5 DC FUSE DC FUSE The DC protector automatically switches to OFF when the current of the operating electrical device is higher than the rated current To use this equipment again turn...

Page 13: ...dry soft cloth as the fuel may harm painted surfaces or plastic parts IMPORTANT Use only unleaded gasoline Using leaded gasoline can cause serious damage to the inside of the engine IMPORTANT CHECKIN...

Page 14: ...fied electrician responsible for the installation and electrical connection of the equipment according to local laws and regulations The manufacturer assumes no lia bility for improper connection of t...

Page 15: ...ngine switch to the RUN position fig 1 FOR MODELS KS 4100 FOR MODELS KS 4100iiE KS 8100 E KS 8100iiE KS 4000 E KS 4000iiE S KS 6000 E S KS 6000iiE S KS 8100 E S KS 8100iiE ATSR KS 6000 E ATSR KS 6000i...

Page 16: ...or stops completely Then start the generator on LPG You can also drain the remaining gasoline from the carburetor before starting the generator on LPG KS 2000iG S D 4 Connect the hose end with the red...

Page 17: ...the generator and only with a low load Failure to comply with this requirement may result in generator failure and void warranty repair Fuel can be changed without stopping the generator When switchin...

Page 18: ...g 7 Fig 6 CHARGING AN EXTERNAL 12 V BATTERY CHARGING AN EXTERNAL 12 V BATTERY 1 Start the engine 2 Connect the red wire to the positive terminal of the battery 3 Connect the black wire to the negative...

Page 19: ...attery charging turn on the DC fuse by pressing the ON button Never smoke or interrupt battery connections to the generator while the battery is being charged ATTENTION DANGER If the generator often o...

Page 20: ...is to be squeezed out SPARK PLUGS TECHNICAL MAINTENANCE 13 Spark plug has to be intact without soot deposits and to have a correct gap SPARK PLUG VERIFICATION SPARK PLUG VERIFICATION 1 Remove the cap...

Page 21: ...nded to store and use the generator at temperature of 20 to 40 Avoid direct sunlight rain on the generator When using and storing hybrid generator gas tank should be kept indoors at temperatures below...

Page 22: ...failures Possible reason Solution Engine does not starting Engine starting swinch set to OFF position Set the engine starting switch to ON Fuel valve set to off position Turn the valve to ON position...