konner-sohnen.com
|
12
FUEL TANK CAP AIR VENT (FOR MODEL KS 2000
FUEL TANK CAP AIR VENT (FOR MODEL KS 2000
ii S)
S)
The fuel cap is equipped with a vent for air supply to the fuel tank. When the engine is running, the vent
must be in the “ON” position (OPEN). This will allow fuel to enter the carburetor for engine operation.
After
the generator stops, allow it to cool down and close the air vent on the fuel cap. When the generator is not
in use, close the vent to the “OFF” position.
EARTHING BOLT
EARTHING BOLT
In all cases, except for an IT system with an insulated neutral wire and bonding, the generator earthing bolt
must be connected to the grounding circuit with a flexible copper conductor with a cross-sectional area of
at least 6 mm
2
.
CHECKING THE FUEL LEVEL
CHECKING THE FUEL LEVEL
1. Unscrew the fuel cap and check the fuel level in the tank.
2. Fill the fuel tank to the fuel filter level.
3. Tighten the fuel cap securely.
4. For silent models of inverter generator, open the air intake vent on the fuel cap.
Recommended fuel:
Recommended fuel: unleaded fuel.
Fuel tank volume:
Fuel tank volume: see specifications table.
CHECK BEFORE GETTING STARTED
6
Wipe up spilled fuel immediately with a clean, dry, soft
cloth, as the fuel may harm painted surfaces or plastic
parts.
IMPORTANT!
Use only unleaded gasoline. Using leaded gasoline can
cause serious damage to the inside of the engine.
IMPORTANT!
CHECKING THE OIL LEVEL
CHECKING THE OIL LEVEL
The generator is transported free of motor oil. Do not start the engine until it is filled with sufficient amount
of motor oil.
1. Unscrew the oil dipstick and wipe it out with a clean cloth.
2. Insert the dipstick without screwing it in.
3. Check the oil level by a mark on the oil dipstick.
4. Add oil if its level is below the mark on the oil dipstick.
5. Screw on the dipstick.
Recommended motor oil:
Recommended motor oil: SAE 10W30, SAE 10W40.
Recommended motor oil grade:
Recommended motor oil grade: API Service SG type or higher.
Motor oil quantity:
Motor oil quantity:
see specifications table.
FILL TO HERE
FILL TO HERE
Before starting the engine,
Before starting the engine, make sure that the rated power of power consumers matches with the power
of generator. Do not exceed the nominal power of the generator. Do not connect any devices before you
Do not connect any devices before you
start the engine!
start the engine!
GETTING STARTED
7
Do not change the controller settings in terms of the
amount of fuel or speed governor (this adjustment
was made at the factory). Otherwise, this may result in
changes in the engine operation or its failure.
IMPORTANT!