10
Heating during the transition period
Prerequisite for the stove to function well is the cor-
rect delivery pressure (chimney draught). This very
much depends on the external temperature. There-
fore, if the external temperatures are high (above
16°C) the delivery pressure can be disrupted.
What to do?
•
Open the primary air controller as far as possible.
•
Only put on a small quantity of fuel.
•
Frequently stoke the ash.
Special information
The manufacturer’s guarantee expires if the stove is
significantly or permanently overloaded above the
nominal heating output, or if fuels other than those
listed are used.
•
The stove must only be used with the combustion
chamber doors shut
•
Never remove hot ashes. Only store ashes in a
fireproof, non-combustible container.
•
Attention:
The surfaces get hot! Always use the
enclosed glove when operating the stove.
•
Never use white spirit, benzene or other inflam-
mable, hazardous materials to ignite the fire.
•
The combustion air supply fittings must never be
altered. In particular, it must be ensured that any
necessary combustion air pies are open while the
fireplace is being used.
•
Do not make any changes or modifications to the
stove
Cleaning
What? How
often?
Using
what?
Inside of stove
at least 1x per year
hand brush,
vacuum cleaner
Connection piece
at least 1x per year
hand brush,
vacuum cleaner
Glass panel
as required
when cold,
using glass cleaner for stoves and
over glass