MOUNTING LIGHT(S) TO THE STAND
ATTENTION!
Do not underestimate the weight of the lights
4
placement and extension of the lights must be
4
carried out by physically fit technicians.
4
Firmly grasp the tubes and secure with
4
the locking pin.
MOVING THE LIGHT STAND (LOAD)
Technicians:
FP - First Person:
operates the distance rod
with the weight
SP - Second Person:
operates the clamping bracket's clamping
screw and locking pin
Order when extending the stand:
FP
5
holds the extension tube
SP
6
loosens the clamp screw
6
and holds it
7
pulls the locking pin until
7
the locking pin is no longer
7
in the locked position
FP
8
extends the extension tube and
8
lighting to the desired approx. height;
8
NOTE:
8
to find the pin hole easily the
8
locking pin should be
8
placed just above the hole
SP
9
let go of the locking knob,
9
so that the pin can click into
9
the extension tube
FP
10
slowly lowers the extension tube
10
until the locking pin locks
11
NOTE:
11
The engagement is normally
11
clearly audible (click) - in any
11
case the control knob must be
11
in contact with the hexagon
SP
12
tightens the clamping screw
12
(manual strength is enough)
NOTE:
Make sure that the "second person" immediately tightens
the clamping screw
12
if the “first person” cannot securely
hold the extension tube.
The load is retracted in reverse order.
USAGE NOTES / FUNCTION
Application examples (not included delivery)
TECHNICAL DATA
KÖNIG & MEYER
GmbH & Co. KG
Kiesweg 2, 97877 Wertheim, www.k-m.de
24623-000-55/76 Rev.06 03-80-856-00 2/20
Material
Tubes: Steel, black powdered
Clamp: Zinc, black powdered
Thread, spring-loaded bolt: Galvanized steel, nickel-plated
Handles: PA
Load
max 18 kg centered
Dimensions
Height: 1400 - 2400 mm, extension tube: ø 35 mm
Box
inside: 1500 x 115 x 50 mm
Weight
3.9 kg
CHECK, MAINTENANCE, CLEANING
- Gentle handling preserves the telescopic faculty, the load capacity
-
and the safety of the installation
- Care and maintenance work may only be carried out when the unit is unloaded
- Damaged parts may not be reused and should be replaced or repaired
- Dirt, moisture and if necessary, any corrosion must be removed
- During maintenance work pay attention to possible hazards (jamming, bumping, tilting)
-
and proceed accordingly
- For cleaning and care use a slightly damp cloth and a non-abrasive cleaning agent
FAULT-FINDING (F) and REPAIR (R)
F: Installation wobbles or is crooked:
F:
R: Eliminate floor unevenness
F:
R Check the base plate
F:
R: Check the tightness of the M20 thread and tighten if necessary
3.a
F:
R: Tighten the clamping screw
12
F:
R: Check the pipe combination for straightness
F:
R: Check the firm seat of the load and if necessary, tighten M10 thread
F: Extension tube wobbles or retracts:
F:
R: Tighten clamping screw
12
F:
R: Check spring-loaded bolt
11
for engagement