background image

24623 Distance rod

 

INTENDED USE 
K&M Solo Distance rod for Lighting stand 24624   
FEATURES & EFFICIENCY 
- Maximum centric load capacity 18 kg 
- Height-adjustable rod combination  

-

 (with spring-loaded bolt) 

- with M20 connection thread  

-

 (for base plate 26705 – 550 x 550 mm) 

- Height 1400 - 2400 mm; extension: ø 35 mm,  

-

 M10 threaded bush

SAFETY INSTRUCTIONS

A. GENERAL

 

A.

 - Ensure a level and load-bearing substrate 

A.

 - First carry out a visual inspection to ensure that the product, base  

A.

 

-

 plate and load are complete and visibly in order 

A.

 

-

 Damaged parts must not be used and should be replaced or  

A.

 

-

 repaired 

A.

 - Assembly, loading and handling only by adequate personnel   

A.

 

-

 (technically and physically suitable persons)  

A.

 - Careful handling is required, as the adjustment possibilities involve  

A.

 

-

 the risk of trapping (wear protective gloves if necessary) 

A.

 - For indoor use only 

 

B.1 LOAD BEARING CAPACITY and B.2 STABILITY

 

Both cannot be separated from each other  
and also always refer to the complete  
INSTALLATION (= combination of base plate,  

INSTALLATION (=

 distance rod and load capacity) 

1. Max. 18 kg when centric load, subject to:     
2. 5° tilting test according to DGUV 17, 18, test conditionsn: 

2.

 The installation is adjusted deliberately as unfavourable as possible  

2.

 (max. height, load placed off-centre, if applicable) uand should not  

2.

 fall over on a plane inclined 5°. 

WARNING!  

2.

 When carrying out this test safety must be ensured, that implies   

2.

 timely interception of the installation, barriers, safety ropes   

2.

 (call in qualified personnel if necessary) 

NOTE: 

2.

 The 5° tilt test shows how well the installation resists possible  

2.

 lateral forces (wind, impacts). 

2.

 It does NOT mean that installation is allowed to operate on a up    

2.

 to 5° inclined floor level. In fact, only level floors are permitted.  

MEASURES to ensure STABILITY: 

2.

 - Make sure the floor is level and stable 

2.

 - Prevent lateral forces (wind, impacts) 

2.

 - Reduce height (retract distance rod) 

2.

 - Reduce the weight of the load 

2.

 - Rope down 

2.

 - Keep unauthorized persons away from the installation 

Basically, the installation must not be at risk to tip over - even when  
the setting is most unfavourable. 

 

C. ASSEMBLY, OPERATION, DISASSEMBLY

     

INSTALLATION:  

2.

 - The screw connection between distance rod and base plate must  

2.

 

-

 always be pushed until stop 

3.a

 

2.

 - Check the strength of this connection regularly 

OPERATION:  

2.

 - Always load the distance rod centrically, as eccentric loads  

2.

 

-

 impair the stability 

2.

 - The spring-loaded bolt 

13

 must always be engaged and   

2.

 

-

 the clamping screw 

14

 must be firmly tightened 

2.

 - Never loosen spring-loaded bolts and clamping screws unchecked,   

2.

 

-

 i.e. in this case the pull-out tube should always be held by a  

2.

 

-

 suitable person 

7

 

DISMANTLING:  

2.

 - First remove load from the extension tube and then unscrew the  

2.

 

-

 distance rod from the subwoofer 

 

D. RISK OF SIDE FORCES

     

Lateral forces must be absolutely avoided, they: 

a

 increase the risk of tipping and  

b

 generate large leverage forces, which result in a heavy strain on the   

b

 threads of the Distance rod and on the base plate especially if the   

b

 threads are not screwed together gap-free, and therefore always   

b

 make sure that the screw connection is tightened firmly. 

Lateral forces arise (often unintentionally) from: 

c

 off centre of load balance 

d

 shocks, contacts, vibrations, wind and uneven, sloping surfaces 

e

 the attempt to tug around the loaded installation

1

 Remove the distance rod from the box  

 

2

 Screw the clamping screw into the clamp 

 

3

 Screw the base tube with the threaded bolt M20  

3

 firmly into the base plate until stop. 

 

3.a WARNING!

 

3.a

 

No gap is allowed between tube and plate. 

3.a

 

Check regularly screw connection and  

3.a

 

retighten if necessary.

Thank you for choosing this product. Please read and follow these 
instructions carefully before installation and use. They inform you about 
all important steps regarding assembly and handling. We recommend 
that you keep them for future reference.

INSTALLATION INSTRUCTIONS

26705-000-56 

Base plate

Summary of Contents for 24623

Page 1: ...stanzrohr einfahren 2 Gewicht der Traglast reduzieren 2 mit Seilen abspannen 2 Unbefugte von der Installation fernhalten Grunds tzlich darf die Installation nicht Gefahr laufen umzukippen auch bei ung...

Page 2: ...t das Auszugrohr mit der Last ZP Zweite Person bedient Klemmschraube und Rastbolzen der Spannschelle Reihenfolge beim Ausfahren EP 5 h lt Auszugrohr fest ZP 6 lockert Klemmschraube 6 und h lt diese fe...

Page 3: ...Reduce height retract distance rod 2 Reduce the weight of the load 2 Rope down 2 Keep unauthorized persons away from the installation Basically the installation must not be at risk to tip over even wh...

Page 4: ...sion tube The load is retracted in reverse order USAGE NOTES FUNCTION Application examples not included delivery TECHNICAL DATA K NIG MEYER GmbH Co KG Kiesweg 2 97877 Wertheim www k m de 24623 000 55...

Page 5: ...ammen mit einer Basis Bodenplatte oder Subwoofer herstellen SICHERHEITSHINWEISE Die Installation muss ausreichend gegen die Gefahr des Kippens gewappnet sein Dies gilt als gegeben wenn die sie den Pr...

Page 6: ...iesem Fall sind es max 18 kg B Die Standsicherheit Tragkraft wie viel kg kann es unter den rtlichen B Gegebenheiten tragen bevor es kippt kg Bestehen des 5 Kipptestes vor Ort B Achtung Die Sicherheit...

Page 7: ...base base plate or subwoofer SAFETY INSTRUCTIONS The installation must be adequately protected against the risk of tipping This is considered to be the case if it meets the test criteria of the stand...

Page 8: ...load bearing capacity how many kg can it carry under local conditions B before it tilts kg passing the 5 tilting test on site B Attention Ensure the safety of the test The lower of the two values app...

Reviews: