background image

E-18

6. Plug in the power cord.

VI.Serial Number Registration

Register the serial number of the PB-501 that has
been installed to the machine.
The location of the serial number is shown in the fig-
ure below.

[For the 1050 series]

[For the C6500/C6501 series]

A075IXE018SA

Power cord

A075IXE048CA

Step

1. Plug the power cord into the outlet and turn

ON the Main power switch.

2. Enter Service mode.

Note:

Refer to procedures in the Service Manual to
enter into the Service Mode.

3. Touch “System Setting” to display sub menus.
4. Touch “M/C Serial Number Setting” from the

system setting sub menus.

5. Touch the finisher No. key according to the

place where it was installed to display the
Serial number entry screen.

    * M PB-501

: Finisher 1

Mother  PB-501

: Finisher 2

other o PB-501

: Finisher 3

6. Enter the serial number of the PB-501 and

touch “OK”. (Use “Shift” to switch between
upper case letters and lower case letters.)

7. Touch “OK” on the serial number list screen.

Step

1. Plug the power cord into the outlet and turn

ON the Main power switch.

2. Enter Service mode.

Note:

Refer to procedures in the Service Manual to
enter into the Service Mode.

3. [Service Mode Menu screen]

Touch “System Setting”.

4. [System Setting Menu screen]

Touch “M/C Serial Number Setting”.

5. Touch the finisher No. key according to the

place where it was installed to display the
Serial number entry screen.
   * M PB-501

: Finisher 1

Mother  PB-501

: Finisher 2

other o PB-501

: Finisher 3

6. Enter the serial number of the PB-501 and

touch “OK”. (Use “Shift” to switch between
upper case letters and lower case letters.)

7. Touch “Return” on the serial number list

screen.

Summary of Contents for PB-501

Page 1: ...01 LS 501 E 12 page PB 501 FD 501 E 14 page Common operations after installing PB 501 E 17 page to 19 page PB 501 RU 503 C6500 C6501 Series E 7 page PB 501 SD 501 RU 503 E 10 page PB 501 LS 501 RU 503...

Page 2: ...ers on the book receptacle 2 may be deformed because the casters on the book receptacle 2 are too weak to support the weight of the whole PB 501 1 Book receptacle 2 2 Book receptacle 3 PB 501 Main uni...

Page 3: ...ces 6 Push back the glue injector Note Push the upper right part of the glue injector cir clemarked part 7 Using the screw holes in the place the lower right locking material was removed install the p...

Page 4: ...s OFF and unplug the power cord 2 Install the Installation plate 1 the Installation plate 2 the Installation plate 3 and the Installation plate 5 on the left side of the machine as below TP screw M4x6...

Page 5: ...e 2 with a screw TP screw M4x10 1 pc 4 Pull out the cover tray and install the Installa tion plate 4 TP screw M4x10 1 pc Note If the screw holes of the Installation plate 2 and the Installation plate...

Page 6: ...ve the short connector from the clamp 9 Connect the short connector to the CN 29 and secure the connector 29 with the clamp 10 Install the top cover on the book receptacle 2 screws 11 Perform a softwa...

Page 7: ...ll out the cover tray and install the Installation plate 4 TP screw M4x10 1pc Note If the screw holes of the Installation plate 4 do not align adjust them by the height of the casters on the PB 501 In...

Page 8: ...lation plate R and machine installation plate L and slide it all the way in until it stops at the back 10 Remove the lock shaft of the conveyance unit 1 black screw Note Be sure to store the lock shaf...

Page 9: ...ut the wire bundle into the RU machine so that it will not get hooked when the conveyance segment is pulled out 16 Install the back cover included with the RU Truss screw black M4x6 2 pcs included wit...

Page 10: ...allation plate 3 and the Installation plate 5 on the left side of the SD 501 SD 506 as below TP screw M4x6 8 pcs 3 Remove the connector cover on the left side of the SD 501 SD 506 1 screw 15AQIXE061SA...

Page 11: ...a screw TP screw M4x10 1 pc 4 Pull out the cover tray and install the Installa tion plate 4 TP screw M4x10 1pc Note If the screw holes of the Installation plate 2 and the Installation plate 4 do not...

Page 12: ...lling PB 501 page 17 to 19 1 Turn the machine s Sub and Main power switches OFF and unplug the power cord 2 Install the Installation plate 1 the Installation plate 2 the Installation plate 3 and the I...

Page 13: ...a screw TP screw M4x10 1 pc 4 Pull out the cover tray and install the Installa tion plate 4 TP screw M4x10 1pc Note If the screw holes of the Installation plate 2 and the Installation plate 4 do not...

Page 14: ...lling PB 501 page 17 to 19 1 Turn OFF the machine s Sub and Main power switches and unplug the power cord 2 Install the Installation plate 1 the Installation plate 2 the Installation plate 3 and the I...

Page 15: ...501 FD 503 2 Align the top hole with the Installation plate 1 and the bottom hole with the Installation plate 5 and slide them to the back 3 Secure the PB 501 onto the Installation plate 2 with a scr...

Page 16: ...e DIP SW1 For the 1050 series only Note This procedure is required because by default it is set for a C6500 C6501 series Factory default of SW1 ON Do not change other switches 10 Install the top cover...

Page 17: ...eptacle 2 so that the two casters come in contact with the floor on which the receptacle is to be installed Note The book receptacle is shipped with casters in a retracted condition Adjust the cover c...

Page 18: ...hine other option PB 501 Finisher 2 Machine other optionx2 PB 501 Finisher 3 6 Enter the serial number of the PB 501 and touch OK Use Shift to switch between upper case letters and lower case letters...

Page 19: ...nit and raise it to acti vate the FD full detection IX Confirmation of Paper Output Output paper If bind results are not good adjust the settings See the Service Manual for adjustment method X Adjustm...

Reviews: