Test mode
FS-501 Field Service Ver2.0 Sep. 2004
3-8
III
Ad
ju
stmen
t/
S
et
ti
n
g
5.3
Operation in each test mode operation
5.3.1
1st Tray Exit
5.3.2
Elevator Tray Exit
5.3.3
Finisher Tray Exit
5.3.4
Shifting Operation
S1-FN:ON
S2-FN:ON
Motors and solenoids: Energized
Entrance Motor (M1-FN), Upper Entrance Motor (M4-FN), Upper/
Lower Entrance Switching Solenoid (SL1-FN), 1st Tray Entrance
Switching Solenoid (SL2-FN)
Motors and solenoids: Deenergized
(Entrance Motor (M1-FN), Upper Entrance Motor (M4-FN), Upper/
Lower Entrance Switching Solenoid (SL1-FN), 1st Tray Entrance
Switching Solenoid (SL2-FN)
S1-FN:ON
S2-FN:OFF
Motors: Energized
(Entrance Motor (M1-FN), Lower Entrance Motor (M2-FN), Exit
Motor(M3-FN)
Motors: Deenergized
(Entrance Motor (M1-FN), Upper Entrance Motor (M4-FN), Lower
Entrance Motor (M2-FN), Exit Motor (M3-FN)
S1-FN:ON
S2-FN:OFF
Motors and solenoids: Energized
(Entrance Motor (M1-FN), Upper Entrance Motor (M4-FN), Lower
Entrance Motor (M2-FN), Exit Motor (M3-FN), Upper/Lower
Entrance Switching Solenoid (SL1-FN)
Motors and solenoids: Deenergized
(Entrance Motor (M1-FN), Upper Entrance Motor (M4-FN), Lower
Entrance Motor (M2-FN), Exit Motor (M3-FN), Upper/Lower
Entrance Switching Solenoid (SL1-FN)
S1-FN:ON
S2-FN:ON
The Elevator Tray shifts to the front.
The Elevator Tray shifts to the rear.
Summary of Contents for FS-501
Page 1: ...SERVICE MANUAL 2004 09 Ver 2 0 FS 501 THEORY OF OPERATION ...
Page 2: ......
Page 4: ......
Page 6: ...FS 501 Theory of Operation Ver2 0 Sep 2004 ii I Outline II Composition Operation ...
Page 10: ...Product specification FS 501 Theory of Operation Ver2 0 Sep 2004 1 4 I Outline Blank page ...
Page 31: ...SERVICE MANUAL 2004 09 Ver 2 0 FIELD SERVICE FS 501 ...
Page 32: ......
Page 34: ......
Page 46: ...Other FS 501 Field Service Ver2 0 Sep 2004 2 4 I General II Maintenance Blank page ...