Trouble code
FS-501 Field Service Ver2.0 Sep. 2004
4-8
IV
T
rou
b
lsh
oot
in
g
2.2.1
How to reset
• Press the Trouble Reset Switch on the Tech. Rep. Setting Switches Board to reset the
following malfunctions: scanner-related malfunctions, fusing-related malfunctions, expo-
sure lamp-related malfunctions and C3FFF.
• For any other malfunctions, open and close the Front Door or turn OFF and ON the
Power Switch.
C0BA0
Elevator Motor (M7-FN) drive
malfunctions
• The Elevator Tray Upper Limit Sensor PQ (PWB-D FN)
is not activated even after the lapse of a given period of
time after M7-FN has been energized (to start raising
the Elevator Tray).
• The Elevator Tray Upper Limit Switch (S2-FN) or Eleva-
tor Tray Lower Limit Switch (S3-FN) is actuated after
M7-FN has been energized.
Code
Item
Description
Summary of Contents for FS-501
Page 1: ...SERVICE MANUAL 2004 09 Ver 2 0 FS 501 THEORY OF OPERATION ...
Page 2: ......
Page 4: ......
Page 6: ...FS 501 Theory of Operation Ver2 0 Sep 2004 ii I Outline II Composition Operation ...
Page 10: ...Product specification FS 501 Theory of Operation Ver2 0 Sep 2004 1 4 I Outline Blank page ...
Page 31: ...SERVICE MANUAL 2004 09 Ver 2 0 FIELD SERVICE FS 501 ...
Page 32: ......
Page 34: ......
Page 46: ...Other FS 501 Field Service Ver2 0 Sep 2004 2 4 I General II Maintenance Blank page ...