FS-501 Field Service Ver2.0 Sep. 2004
Trouble code
4-13
IV
T
rou
b
lsh
oot
in
g
2.3.6
C0B80:Shift Motor (M8-FN) drive malfunctions
A. Detection timing
B. Action
Malfunction code
Description
C0B80
The Shift Home Position Sensor (PC10-FN) does not go HIGH even after the lapse
of a given period of time after M8-FN has been energized (to start returning the
Elevator Tray to its home position).
The Shift Home Position Sensor (PC10-FN) does not go LOW even after the lapse
of a given period of time after M8-FN has been energized (to start moving the Ele-
vator Tray for job offset).
Relevant electrical parts
Shift Home Position Sensor (PC10-FN)
Shift Motor Pulse Sensor (PC11-FN)
Shift Motor (M8-FN)
Control Board (PWB-A FN)
Step
Action
WIRING DIAGRAM
Control signal
Location
(Electrical compo-
nents)
1
Check the motor and sensor connectors
for proper connection, and correct as
necessary.
-
-
2
Check the connector of motor for proper
drive coupling, and correct as neces-
sary.
-
-
3
PC10-FN I/O, sensor check
PWB-A FN PJ25A FN-12
H-2
4
PC11-FN I/O, sensor check
PWB-A FN PJ25A FN-14
H-2
5
M8-FN operation check
PWB-A FN PJ5A FN-3,4
D-2
6
PWB-A FN replacement
-
E-5
Summary of Contents for FS-501
Page 1: ...SERVICE MANUAL 2004 09 Ver 2 0 FS 501 THEORY OF OPERATION ...
Page 2: ......
Page 4: ......
Page 6: ...FS 501 Theory of Operation Ver2 0 Sep 2004 ii I Outline II Composition Operation ...
Page 10: ...Product specification FS 501 Theory of Operation Ver2 0 Sep 2004 1 4 I Outline Blank page ...
Page 31: ...SERVICE MANUAL 2004 09 Ver 2 0 FIELD SERVICE FS 501 ...
Page 32: ......
Page 34: ......
Page 46: ...Other FS 501 Field Service Ver2 0 Sep 2004 2 4 I General II Maintenance Blank page ...