WARNING:
The appliance
should not be mounted on the
stairs, exits or hallways of the
building.
The stable pressure by which the
air conditioner is experienced is
100 Kpa.
The fuse that should be used in
the electrical connection of the
air conditioner is type C 16 A for
9,000 and 12,000 btu and type
C 20 A for 18,000 and 24,000
btu.
Care should be given to the
wire diameter cross-section in
the electrical wiring of the place
where the air condition will be
installed.
Only the outdoor unit of your
air conditioner is proper for use
outside the building.
Choosing the Mounting
Position
Indoor Unit
• There should not be any va-
pour or heat source near the
air conditioner.
• There should not be any ob-
stacle preventing air circula-
tion at the mounting posi-
tion.
• Air circulation should be suf-
ficient.
• Discharge should be easily
executable.
• It should not be close to the
door entrance.
• There should be enough dis-
tance between the air con-
ditioner and the wall, ceiling,
decorations and other ob-
stacles.
• The mounting position
should be about 30 centime-
tres below the ceiling.
Outdoor Unit
• If there is an awning protect-
ing the outdoor unit from
sunlight or rain, make sure
that it does not prevent con-
denser from distributing the
heat.
• There should be enough dis-
tance between the air con-
ditioner and the wall, ceiling,
decorations and other ob-
stacles.
11