Komptec GmbH. KT-90A User Manual
Page 24 of 52
v1.0a; 8 May 2016
Installation in enclosed spaces:
l
Ensure adequate ventilation
l
Intake air must be free of harmful gases, eg Fumes, solvent fumes
l
If possible, install system so that the fan of the compressor may suck in fresh air for
cooling from the outside, for example, through a wall opening. Distance from the
wall is at least 0.5 m.
Outdoor Installation:
l
Provide aggregate on firm surface and up horizontally
l
Make sure that near the intake point are no motor vehicles with the engine running.
l
Physical Do not operate near open flames (fumes!)
6.3.
Placement
Place the unit on a firm surface
Place the unit horizontally
Space required for the Compressor
F
The compressor must not be placed directly on the wall. Minimum dis-
tance from the wall is 0.5m.
F
The ambient temperature must be no higher than + 35 ° C and not lower
than + 5 ° C. A block heater should be used when ambient temperature is
below + 5 ° C. When a block heater is used, operation at temperatures
down to - 5 ° C should be possible, however at temperatures below freez-
ing, there is risk of condensate freezing in external filters and tubing.
i