background image

Operating Instructions

13

FIREplac

E

 O

p

ER
a

TIONS

°F

°C

PM

AM

• HEATER key is used to control ON/OFF of the heater. 

Push UP (“+”) or DOWN  (“-”) key to to scroll through 

the pre-set temperature range from 59°F (15°C) to 

86°F (30°C), ON & OF (OFF). Heater will turned ON 

accordingly to the set temperature. When the ambient 

temperature is higher than the set temperature, heater 

will automatically turned OFF.

• When the temperature is set at “ON”, heater will be 

working continuously.

• When HEATER is activated, the heater & temperature 

symbol will displayed.

• When the heater is ON, hold the HEATER key for 3 

sec; this allow the temperature unit change from °C to 

°F or °F to °C. The unit default setting is °F.

• Press the POWER button to turn ON or OFF the unit.

• When the unit is in ON mode, touch control panel light 

will fully light up for 8 sec and then shut down if without 

any others operation including remote control.

• When the unit is in OFF mode, the POWER symbol 

LED will Semi-bright. When power OFF, unit will be 

stopped, if heater is working before power OFF the 

unit, fan will have 20 seconds delay to ensure heat will 

not be trapped inside the unit.

Flame Brightness Setting

• Press “Flame” key until FL0 / FL1 / FL2 / FL3 / FL4 / 

FL5 shown on the display, and then press “+” key or “-” 

key to adjust the flame brightness from level 0 to level 5.

Timer Setting

• Timer  can  be  adjusted  when  heater  is  ON.  It  can 

adjusted from 0 hour (OFF) to 9 hours with 0.5 hour 

interval.

• When TIMER is activated, the symbol will be displayed.
• When TIMER digital is 0 H, TIMER function is invalided. 

The TIMER symbol will automatically disappear.

clock Setting

• For clock setting, hold the TIMER key for 5s, hour 

display will flashing. Push UP “+” or DOWN “-” key, 

Hours setting can be adjusted. Touch the TIMER key 

once more, minute display will flashing. Minutes setting 

can be adjusted as the same way as hours setting.

• When clock is at the setting mode, hold UP (“+”) and 

DOWN (“-”) keys together to select 12H or 24H mode. 

The unit default setting is 24H. The  AM or PM symbol 

will automatically displayed when the 12H mode was 

selected.

•  Press  the  timer  key  can  exit  the  setting  or  it  will 

automatically exit after 8s without any further operation.

power Button

Each time the fireplace is plugged in, a 5-second fan and 
heater will turn on for internal check program.
The unit has a memory function with last settings for 
heating level and flame brightness effect, unless the main 
power to the unit has been interrupted.

Flame Button

Heater Button

Timer Button

activate child lock

• When the unit is ON, hold the POWER button for 10 

seconds to activate the Child Lock function. "E3" will be 

displayed and a "beep" will sound 3 times to indicate the 

Child Lock function is activated. Then, all function keys are 

locked. When pressing any button, "E3" will be displayed 

to indicate the Child Lock function has been activated.

Deactivate child lock

• To deactivate the Child Lock function, hold the POWER 

button for 10 seconds. Then, all functions keys are 

unlocked.

• Control the setting of flame brightness, flame color, 

mood light brightness, mood light color, timer, clock and 

temperture .

child lock

Up Button ;

Down Button

Summary of Contents for SP5735

Page 1: ...ference QUESTIONS PROBLEMS OR MISSING PARTS Please Contact Customer Service Before Returning to Store Please carefully check the unit and make sure there is no damage when you open the carton services...

Page 2: ...rounded in accordance with local codes with the current CSA C22 1 Canadian Electrical Code or for USA installations follow the National Electrical Code ANSI NFPA NO 70 This equipment has been tested a...

Page 3: ...e DO NOT block any air intakes or exhaust in any manner DO NOT use on soft surfaces like a bed where opening may become blocked ALWAYS plug this unit directly into a wall outlet receptacle NEVER use w...

Page 4: ...ith the electric fireplace 7 Any installation labor construction transportation or other related costs expenses arising from defective part s repair replacement or otherwise of same will not be covere...

Page 5: ...losed wall anchors BB only can be use on the concrete wall 6 For the best effect install the fireplace out of direct sunlight and away from overhead lighting Tools Required Philips Screwdriver Hand Dr...

Page 6: ...SSEMBLY INSTRUCTIONS x 1 x 1 x 1 A C B Front Cover Base Fireplace x 1 x 1 x 1 Mounting Bracket Remote Control Acrylic Shards D E F A C D B E F Number of spare hardware is indicated in Hardware Identif...

Page 7: ...sembly Wall Mount Installation 2 Remove mounting bracket D from back of fireplace C by unscrew two screws at the top of the unit D D Remove the base B of fireplace C by unscrewing three screws at the...

Page 8: ...t D to the wall with toggle bolts and washers not included CONCRETE WALL Drill 5 16 inch holes at marked locations then insert wall anchors BB into holes Secure the mounting bracket D to wall using sc...

Page 9: ...STRUCTIONS 5 6 Hang the fireplace C on the hooks at bottom of mounting bracket D and push the fireplace C into mounting bracket D Re fasten the two screws removed in Step 1 Distribute the Acrylic Shar...

Page 10: ...10 ASSEMBLY INSTRUCTIONS Assembly Wall Mount Installation 7 Re install the front cover A to the fireplace C A A C C...

Page 11: ...ding Installation 11 ASSEMBLY INSTRUCTIONS 1 2 Assembly the base B of fireplace C by fasten three screws Release the latches on the both side to unlock the front glass as illustrated below to removing...

Page 12: ...12 ASSEMBLY INSTRUCTIONS Assembly Free Standing Installation 3 4 Distribute the Acrylic Shards F evenly in the tray of the fireplace C Re install the front cover A to the fireplace C F C C C A A...

Page 13: ...ill be displayed When TIMER digital is 0 H TIMER function is invalided The TIMER symbol will automatically disappear Clock Setting For clock setting hold the TIMER key for 5s hour display will flashin...

Page 14: ...fireplace and replace any part of the electrical system WARNING Disconnect the power before attempting any maintenance or cleaning to reduce the risk of fire electrical shock or personal injury WARNIN...

Page 15: ...the unit back in and turn on the heater If the problem persists call customer service 3 Unplug unit wait 5 10 minutes then the sensor will reset itself Plug the unit back in and turn on the heater If...

Page 16: ...ING PARTS Please Contact Customer Service Before Returning to Store Crafted in China Distributed by Soupro Limited Inc 72 Montgomery Court Markham Ontario L3R 0C1 Ver 2 servicespi sourceproinc com 1 8...

Page 17: ...ESTIONS PROBL MES OU PI CES MANQUANTES Contactez le service client le avant de le retourner au magasin V rifiez soigneusement l appareil et assurez vous qu il n y a pas de dommages lorsque vous ouvrez...

Page 18: ...n veillez a ce que l appareil soit mis a la terre conformement aux codes locaux a la plus recente version du Code canadien de l electricite CSA C22 1 ou au code national de l electricite ANSI NFPA No...

Page 19: ...mise la terre Ne vous servez pas de l adaptateur si une prise trois fentes avec mise la terre est disponible AVIS IMPORTANT Quand vous utilisez un appareil electrique des precautions de base devrait e...

Page 20: ...es frais et ou depenses decoulant de la piece defectueuse de la reparation du remplacement ne sera pas couvert par cette garantie et la Compagnie n en assume pas la responsabilite 8 Le propri taire ut...

Page 21: ...peuvent seulement tre utilize sur un mur de b ton 6 Pour un meilleur effet installer le foyer hors des rayons directe du soleil et loin de l clairage du plafond Outils requis Tournevis cruciforme Per...

Page 22: ...CTIONS DE MONTAGE Nombre de materiel en est separe pour la sauvegarde Identification de la quincaillerie x 1 x 1 x 1 A C B Couvercle avant Base Foyer x 1 x 1 x 1 Support de Montage T l commande Pierre...

Page 23: ...GE Assembl e Installation Murale 2 Retirez le support de montage D a l arriere du foyer C en devissant les deux vis en haut de l unite Retirez la base B du foyer C en d vissant les 3 vis la base arri...

Page 24: ...boulons ailettes et des rondelles non inclus MUR DE B TON Percer des trous de 5 16 pouces aux endroits marqu s puis ins rez les ancrages BB dans les trous Fixer le support de montage D au mur en util...

Page 25: ...DE MONTAGE 5 6 Accrocher le foyer C sur les crochets en bas du support de montage D et pousser le foyer C dans le support de montage D Resserrez les deux vis retir es l tape 1 Distribuer les pierres...

Page 26: ...26 INSTRUCTIONS DE MONTAGE Assembl e Installation Murale 7 R installer la vitre avant A du foyer C A A C C...

Page 27: ...ase 27 INSTRUCTIONS DE MONTAGE 1 2 Assembler la base B du foyer C en vissant les trois vis Rel chez les loquets sur les 2 c t s la fois pour d verrouiller la vitre avant comme illustr ci dessous pour...

Page 28: ...28 INSTRUCTIONS DE MONTAGE Assembl e Installation Avec Base 3 4 Distribuer les pierres F uniform ment dans le plateau du foyer C R installer la vitre avant A du foyer C F C C C A A...

Page 29: ...l unite R glage de Luminosit de Flamme Appuyez sur la touche Flamme jusqu a FL0 FL1 FL2 FL3 FL4 FL5 s affiche sur l ecran puis appuyez sur la touche ou pour ajuster la luminosite de la flamme du nive...

Page 30: ...mentation de l appareil doit tre mis hors tension Tout d abord tourner l interrupteur d alimentation principal sur la position ARR T Ensuite retirez la fiche lectrique de la prise murale Remarque Lors...

Page 31: ...es le capteur se r initialisera par lui m me Rebrancher l unit et mettre l appareil en marche Si le probl me persiste contacter le service la client le 3 D brancher l unit attendre 5 10 minutes le cap...

Page 32: ...par Soupro Limited Inc 72 Montgomery Court Markham Ontario L3R 0C1 QUESTIONS PROBL MES OU PI CES MANQUANTES Contactez le service client le avant de le retourner au magasin servicespi sourceproinc com...