The accumulator is installed to the position shown in the figure.
METHOD FOR CHECKING FOR MISSING FUEL SPRAY PREVENTION CAP,
HARDENING OF RUBBER
Check fuel spray prevention caps (1) to (14) visually or with a finger to see if any of them has slipped off, or the
rubber portion is hardened.
REMARK
The fuel spray prevention caps (1) to (14) act to prevent the fuel from coming into contact with high-temperature
parts of the engine and causing a fire if the fuel should leak or spray out.
If there are any problems, the related parts must be replaced. Ask your Komatsu distributor for replacement.
EVERY 4500 HOURS MAINTENANCE
Maintenance for every 50, 250 and 500 hours should be performed at the same time.
METHOD FOR CLEANING KDPF
Contact your Komatsu distributor for cleaning of the KDPF.
METHOD FOR CLEANING DEF TANK
Ask your Komatsu distributor for cleaning of the DEF tank.
EVERY 5000 HOURS MAINTENANCE
Maintenance for every 50, 250, 500 and 1000 hours service should be performed at the same time.
MAINTENANCE
MAINTENANCE PROCEDURE