MAINTENANCE
SERVICE PROCEDURE
EVERY 2000 HOURS SERVICE
Maintenance for every 50, 100, 250, 500 and 1000 hours service should be carried out at the same time.
CHANGE OIL IN HYDRAULIC TANK
WARNING
The parts and oil are at high temperature immediately after the engine is stopped, and may cause burns. Wait for the
temperature to go down before starting the work.
When removing the oil filler cap, turn it slowly to release the internal pressure, then remove it.
Refill capacity: 129 liters (34.06 US gal)
1. Lower the dump body and stop the engine.
2. Turn the cap of oil filler (F) to release the internal pressure
before removing the cap.
3. Taking care not to get any oil on you, remove drain plug (P),
drain the oil, then tighten the plug again.
4. Pour in the specified amount of engine oil from oil filler (F).
5. After adding oil, check that the oil is at the specified level. For
details of the oil to use, see "CHECK OIL LEVEL IN
HYDRAULIC TANK, ADD OIL (PAGE 3-65)".
4 - 71