CHECK OIL LEVEL IN ENGINE OIL PAN, ADD OIL
WARNING
Parts and oil are at high temperature immediately after the engine is stopped and may cause serious burns. Wait for the oil
temperature to go down before performing this operation.
1. Check the oil level with dipstick (G).
2. Take out the dipstick (G) and wipe off the oil with cloth.
3. Fully insert dipstick (G) into filler pipe (F), then remove it.
4. The oil level should be between the H and L marks on the
ENGINE STOPPED side of dipstick (G).
If the oil is below the L mark, add oil through oil filler (F).
5. If the oil is above the H mark, remove drain plug (1), and loosen
drain valve (2) to drain the excess engine oil, then check the
engine oil level again.
6. If the oil level is correct, tighten the handle of the oil filler cap
securely.
REMARK
When checking the oil level after the engine has been operated, wait for at least 15 minutes after stopping the
engine.
The dipstick has the oil level marked on both sides: ENGINE STOPPED for measuring when the engine is
stopped, and ENGINE IDLING for measuring when the engine is idling.
When checking the oil level, stop the engine and check with the ENGINE STOPPED side of the dipstick.
It is also possible to check when the engine is idling, but the following procedure must be used.
•
Check that the engine water temperature is in the green range.
•
Use the ENGINE IDLING side of the dipstick.
•
Remove the oil filler cap.
3 - 64
Summary of Contents for Galeo HD325-6
Page 1: ......
Page 2: ... 1 1 ...
Page 4: ... FOREWORD FOREWORD 1 3 ...
Page 5: ... FOREWORD FOREWORD 1 4 ...
Page 14: ... FOREWORD CONTENTS METHOD OF USE 6 49 INDEX 7 1 1 13 ...
Page 15: ... ...
Page 16: ... 2 1 ...
Page 49: ... ...
Page 50: ... 3 1 ...
Page 140: ... OPERATION OPERATION HD325 HD325 of 4WD specifications HD405 3 91 ...
Page 182: ... 4 1 ...
Page 261: ... ...
Page 262: ... 5 1 ...
Page 264: ... 6 1 ...
Page 267: ... ATTACHMENTS OPTIONS HANDLING PAYLOAD METER HD325 HD325 of 4WD specifications 6 4 ...
Page 268: ... ATTACHMENTS OPTIONS HANDLING PAYLOAD METER HD405 6 5 ...