OPERATION
EXPLANATION OF COMPONENTS
3-21
After replacing the indicated filter or oil displayed on display panel B (multi-information), reset the time. For details,
see “METHOD OF USING OIL AND FILTER MAINTENANCE MODE (3-23)“.
The lamp goes out or stops flashing.
METHOD OF USING MAINTENANCE MODE
3
To switch from the operation mode to the maintenance mode,
turn the buzzer switch to the
position and hold it there for at
least 2.5 seconds. The screen will switch to the maintenance
mode.
On the first screen, the oil and filter maintenance mode is dis-
played.
EXPLANATION OF MODES AND OPERATION
The maintenance mode has the following 4 sub modes.
Use information switch (1) and buzzer cancel switch (2) to
operate each mode.
Sub mode
Function
Reference items
Oil/filter maintenance mode
Oil or filter replacement time is
displayed
METHOD OF USING OIL AND FILTER
MAINTENANCE MODE (3-23)
PM clinic auxiliary mode
Engine speed or HST oil tempera-
ture is displayed
METHOD OF USING PM CLINIC AUXIL-
IARY MODE (3-25)
Fault code display mode
Fault codes for electronic control
related parts are displayed
METHOD OF USING FAULT CODE DIS-
PLAY MODE (3-26)
Adjustment mode
Adjusts monitor brightness, etc.
Summary of Contents for D31EX-21