TROUBLESHOOTING
OPERATION
3-124
WHEN ENGINE DOES NOT STOP
3
CAUTION
Do not start the engine again until the repairs are completed.
If the engine does not stop even when the starting switch is turned to the OFF position, use the following proce-
dure to stop the engine.
1. Open the engine side cover on the left side of the chassis.
2. Remove nut (1) of the stop solenoid, then disconnect the
stop solenoid and rod (2).
3. Extend the rod (2) or push lever (3) extending from the fuel
injection pump to the rear and stop the engine.
4. Installed nut (1) of the stop solenoid and connect rod (2).
There is probably a failure or disconnection, so after stopping the engine, contact your Komatsu distributor for
repairs.