SERVICE PROCEDURE
MAINTENANCE
4-32
q
No bubbles in refrigerant flow: Suitable (A)
q
Some bubbles in flow
(bubbles pass continuously): Lack of refrigerant (B)
q
Colorless, transparent: No refrigerant (C)
REMARK
When there are bubbles, the refrigerant gas level is low, so
contact your refrigerant dealer to have refrigerant added. If the
air conditioner is run with the refrigerant gas level low, it will
cause damage to the compressor.
New Freon R134a is used as the refrigerant.
OPERATING AIR CONDITIONER OFF-SEASON
Even during the off-season, operate the air conditioner for 3 to 5 minutes once a month to maintain the oil film at all
parts of the compressor.