background image

Page 5

- - - - - M E N U - - P R : 1 - - - - -

6 ) B r a k e

t i m e :

o f f



7 ) R a m p :

0 . 2 s

8 ) S p e e d :

6 0 0 r p m

6) Brake time:

This option can be selected

U

only

U

in combination with the option JOINT: HARD.

It  indicates  how long  the  selected speed  (higher  speed)  will  be  on  before switching  to  “pre

-

torque  speed”

(lower  speed).  The  “pre

-

torque  speed”

will  be  automatically  chosen  by  the  unit  depending  on  the  preset

torque. You can set the brake time from 0.3 to 10.0 sec.
To disable the function press

until you get to OFF. In this case the screwdriver will automatically start at

pre-torque speed, which cannot be set by the user.

CAUTION: The aim of the BRAKE TIME is only to speed up the approach time in case of long screws.
Reaching  the  torque  at  higher  speed  will  result  in  inaccurate  torque  output.  To  avoid  inaccurate  torque
values we suggest selecting a shorter time, and then increase it step by step until the optimum time.

Torque  reached  during  the  Brake  Time  won’t  activate  the  torque  signal  and  the  message  “

Error  brake

time

” will be displayed on the main screen together with 2 beep sounds. The re

d led will turn on, too.

7) Ramp:

You can select the slow start time (acceleration) from 0.2 to 3.0 sec. This option is only available

for  the  screwing  phase,  while  during  the  unscrewing  phase  the ramp  time  is  always  0.2  sec. We  suggest
using this option with self tapping screws.
ATTENTION: Reaching the torque while the ramp is still on could result in a different torque level from the
one that results when at the end of the ramp. This is due to the motor acceleration.
Reaching  the torque  while the ramp  i

s  still  on  will  activate  the  “

Screw  OK

”  signal anyway  (this  option is

useful if you need to tighten screws that are already tightened, the so called “double hit” ).

On the other hand, if you wish to see an error signal, you can modify the minimum time by setting value
which is equal or superior to the ramp value (see point 10).

8)  Speed:

You can select any speed value of the screwdriver between nominal (maximum speed given in

the catalogue) and the minimum speed of every single screwdriver (see table with technical data).

- - - - - M E N U - - P R : 1 - - - - -

9 ) R u n t i m e :

2 0 . 0 s



1 0 ) M i n

t i m e :

o f f F

1 1 ) M a x

t i m e :

2 0 . 0 s

9)  Runtime:

You can set the time of a tightening, from OFF to 20.0 sec. When the pre-set time has been

reached, it results in a torque signal.
The couple reached during this time results in a signal of Correct screw. If the correct screw signal is not
required, set the Minimum time up to a value of 'Minimum Time -0.1sec'.

ATTENTION: Max Time must be set at 20.0 sec.

10) Min time - Minimum Time:

You can select  the minimum time of screwing from 0.1 sec to 'Max

time - 0.1s'. To disable the function press

until you get to OFF (Min time = 0).

Torque  reached  below  the  minimum  time  won

’t  activate  the  torque  signal  and  will  result  in  an  error

signal. “

Below minimum time

” will be displayed on the status bar and the red led will light up. You will

hear two beep sounds, too.

11) Max time - Maximum time:

You can select  the maximum time of screwing. You can set from 'Min

time + 0,1s' to 20.0 sec.

Summary of Contents for EDU 2AE/TOP/NT

Page 1: ...NSFORMER 230V or 110V AC 50 Hz 40 V DC 200 VA FUSE 3 15 A DIMENSIONS 190 x 205 x h120 mm WEIGHT 4 Kg DECLARATION OF CONFORMITY KOLVER S r l declares that the new tool here described control unit model...

Page 2: ...o select the correct options to ensure that proper torque is being applied Read the menu description carefully and in case you are unsure please contact Kolver for support information Turn the unit on...

Page 3: ...ll the set parameters press for 2 seconds however you cannot modify the displayed parameters on this screen LEDS ON FRON PANEL GREEN LED VERDE indication of Screw OK YELLOW LED indication of Programm...

Page 4: ...A T O 1 5 4 T o r q u e 1 0 5 J o i n t s o f t 3 Model you can select the screwdriver to be used Only NATO models 4 Torque you can select the desired torque as a percentage of the torque range of the...

Page 5: ...n a different torque level from the one that results when at the end of the ramp This is due to the motor acceleration Reaching the torque while the ramp is still on will activate the Screw OK signal...

Page 6: ...r than the possible maximum torque so that it is always possible to unscrew a tightened screw we suggest leaving this function on in normal use If the setting is from MIN to 99 the reverse torque with...

Page 7: ...example after calibration see Torque calibration you make a screwing on your assembly and compare the displayed value to the value you see on a torque tester for example a mini K or a K model Let s sa...

Page 8: ...ode to scan a barcode and recall the desired program To be used in combination with option 4 of the Sequence Menu 28 Serial PRT Serial print from OFF to 5 When OFF no print If it is set up to 5 this v...

Page 9: ...arcode mode OFF barcode disabled ON prog you can select the program to be executed by scanning the bar code of the product The unit compares the scanned code to the one previously entered in each prog...

Page 10: ...password see point 3 OP T I ON ME N U 3 P a s s w o r d o n 4 E S C OK R S T e x t 5 U n i t N m 3 Password ON When YES you will be asked for the password to enter the menu Otherwise select NO ATTENT...

Page 11: ...ME N U 7 S e r i a l n 0 0 0 0 0 0 0 0 8 S e t t i m e d a t e 9 C y c l e s 0 0 0 0 0 0 0 8 Set time date to set time and date on the control unit 9 Cycles Total number of cycles It shows the number...

Page 12: ...torque value on the display of your EDU2AE TOP as you know all information you see on the display can be printed out through the serial port thus helping you to keep trace of all fastening data Let s...

Page 13: ...0 0 0 1 Nm Set the torque value to 1 40 Nm by selecting each digit individually pressing and and press OK to confirmit then press OK again to save You will see S T E P 2 E n t e r t h e p e r c e n t...

Page 14: ...the previous screen Press ESC to stop calibration and then repeat the screwing cycles USE OF T A Torque Angle Choose the T A mode see point 26 Modify function on the program menu It is possible to set...

Page 15: ...will light up and the message tightening OK will be displayed on the status bar If the screwdriver stops before reaching the preset angle the tightening will be considered not ok the red led will ligh...

Page 16: ...The control unit emits sounds which help you understand if the screwing has been carried out correctly or not When the torque is reached meeting all the parameters set the control unit utters a 0 5 s...

Page 17: ...Page 17 I O CONNECTIONS...

Page 18: ...r Screw ok or Error Signal is 24VDC 5 SCREW OK Correct screw signal It activates every time the torque is reached and it resets when the lever or remote start is released Signal is 24VDC INPUT 6 T A I...

Page 19: ...eser remote errors 5 RESET EXT If enabled see point 4 OK ESC commands in the option menu it resets program or sequence according to the preset function see point 5 Reset in the option menu 6 INPUT 8 S...

Page 20: ...parallel with the yellow led on the front panel 4 SEQUENCE END It indicates the end of a sequence if enabled 5 NOK T A It activates if any angle error occurs 6 PR OK It activates at the end of each p...

Page 21: ...indicates you re using program 3 4 OUTPUT 4 It indicates you re using program 4 5 OUTPUT 5 It indicates you re using program 5 6 OUTPUT 6 It indicates you re using program 6 7 OUTPUT 7 It indicates y...

Page 22: ...ption menu remote OK key function 15 ESC EXT If enabled see point 4 OK ESC in the option menu ESC key function to reset remote errors 16 RESET EXT If enabled see point 4 OK ESC in the option menu it r...

Page 23: ...to loading after it s been switched on Contact the nearest Kolver dealer 1 tightened screw is displayed on the status bar the torque signal is displayed during the motor startup process which lasted 0...

Page 24: ...h PROGRAM MENU see point 18 on the program menu 16 Reverse torque error is displayed on the status bar The torque signal is displayed while loosening but only if it s set on max The screwdriver couldn...

Page 25: ...ults on a USB device only on EDU2AE TOP NATO E and EDU2AE TOP NATO TA The transmission characteristics only serial and USB are the following 9600 bits per second 8 data bits n no parity 1 bits stop 1...

Page 26: ...of screws Seq Sequence stage it indicates the stage of the sequence T Torque torque value A Angle angle value Notice in case of program end it prints Program End in case of sequence end it prints Seq...

Page 27: ...on another unit and on EDU EXPAND too Here is a quick guide to use EDU EXPAND Double click the icon program and this is the main view New program to load a new program Load from file it loads all prog...

Page 28: ...nter will not confirm the change Save to file it saves all programs to a file This file can be read directly from a USB drive connected to the unit on its front panel In this case the file name must b...

Page 29: ...n only be initiated if the control unit shows Ready on the main screen Open terminal to display the print string see Serial Print To save in a txt file the results of each tightening push Save Report...

Page 30: ...of charge such items 3 This guarantee does not cover repair or replacement required as a consequence of products which have been abused misused or modified or which have been repaired using not origi...

Reviews: