EB-10X Installation & Service Manual |
Wiring
15
Kollmorgen | kdn.kollmorgen.com | October 2020
Notes for previous diagram:
1. The motor thermostat is an automatic resetting device and should be connected into a
latched (lock-out) power down type circuit.
2. Thermostat to be wired with twisted pair.
3. The brake should be energized before switching the motor on and while it is in operation.
For proper operation an electrical interlock circuit should be employed to ensure that the
brake is not engaged while the motor is energized.
Model
Holding VDC
Holding ADC
EB-10X-X-XX-B2
90
0.18
EB-10X-X-XX-B3
24
0.60
4. Application resolver leads will exit at a different location than system resolver leads.
2.5
3-Phase Power Trans