3.
1.
●
5.
The power cord and control wire can't be crossed or
winding.
The drain hose should be bound at the bottom.
upper hook
indoor unit
band
●
lower hook of
wall-mounting frame
2.
Step 9:
Hang the indoor unit
3.
4.
indoor
wall pipe
4.
2.
outdoor
sealing gum
3.
4.
gas
pipe
liquid pipe
5.
drain hose
indoor and
Step 8:
Bind up pipe
outdoor power cord
1.
The wiring board is for reference only, please refer
to the actual one.
11
Do not bend the drain hose too excessively in order
to prevent blocking.
connection pipe
drain hose
drain hose with the band.
band
indoor power cord
Bind up the connection pipe, power cord and
make them pass through the wall hole.
Hang the indoor unit on the wall-mounting
frame.
Stuff the gap between pipes and wall hole
with sealing gum.
Fix the wall pipe.
Check if the indoor unit is installed firmly and
closed to the wall.
Remove the wire clip; connect the power conn-
ection wire to the wiring terminal according to
the color; tighten the screw and then fix the po-
wer connection wire with wire clip.
blue black brown
Outdoor unit connection
yellow-
green
Put the bound pipes in the wall pipe and then
Bind them evenly.
The liquid pipe and gas pipe should be bo-
und separately a t the end.
N(1)
2
3
NOTICE
NOTICE
NOTICE
Put wiring cover back and then tighten the screw.
Close the panel.
Reserve a certain length of drain hose and
power cord for installation when binding th-
em. When binding to a certain degree, sep-
arate the indoor power and then separate
the drain hose.