Phenomenon

Solution

Eliminate the odour 

source. Clean the 

filter.

Temperature can’t 

be adjusted under 

auto mode. Please 

switch the operation

mode if you need to 

adjust temperature. 

Unit is operating un-

der auto mode? 

Your required temp-

erature exceeds the

set  temperature 

range? 

Whether remote co-

ntroller is within the 

signal receiving range?

Voltage is too low?

Wait until the voltage 

resumes normal.

Remove obstacles.

Select proper angle 
and point the remote 
controller at the rece-

iving window on indoor 
unit.

Clean the filter.

Filter is dirty?

Whether remote co-
ntroller is pointing at 
the receiving window?

Adjust temperature to

proper range. 

Is sensitivity of rem-
ote controller low; 
fuzzy display or no 
display?  

Check the batteries. 
If th e powe r of batteries
is to o low , please rep-

lace them. 

Whether there’s inte-

rference, such as 

thunder, wireless 

devices, etc.

Disconnect power, 

put back power, and 

then turn on the unit 

again.

No display when op-

erating remote cont-
roller?

Check whether rem-

ote controller appears
to be damaged. If yes,

replace it.  

During defrosting

under heating mode, 

it may generate vapor, 

which is a normal 

phenomenon.

Take the remote con-

troller close to indoor

unit. Turn off the fluo-

rescent lamp and then

try it again.

The noise is the sound 

of refrigerant flowing 

inside the unit, which is 

a normal phenomenon.

Eliminate obstacles.

This is the sound of 

friction caused by 

expansion and or 

contraction of panel 

or other parts due to

the change of temp-

erature.

Under heating mode, 

indoor temperature is 

reached to set temp-

erature?

In order to prevent 

blowing out cold air, 

indoor unit will be 

started after delaying 

for several minutes, 

which is a normal 

phenomenon.

Heating mode is 

turned on just now?

WARNING

When below phenomenon occurs,please turn
off air conditioner and disconnect power immedi-
ately, and then contact the dealer or qualified 

 

professionals for service.

 

■ 

Power failure?

Is plug loose?

Reinsert the plug.

Power cord is overheating or damaged.
There’s abnormal sound during operation.
Air switch trips off frequently.
Air conditioner gives off burning smell.

Indoor unit is leaking.

Air switch trips off 

or fuse is burnt out? 

Ask professional to 

 replace air switch or fuse.  

Wiring has malfunc-

tion?

Ask professional to 

replace it. 

Unit has restarted 

immediately after 

stopping operation? 

Wait for 3min, and 

then turn on the unit 

again. 

Do not repair or refit the air conditioner by yourself.
If the air conditioner operates under abnormal 
conditions, it may cause malfunction, electric
shock or fire hazard.

Whether the function 

setting for remote

controller is correct?   

Reset the function.

Because indoor air 

is cooled rapidly. 

After a while, indoor 

temperature and hu-

midity will be decrease 

and mist will disappear. 

Indoor temperature 

  and humidity is high? 

6

Check items

Whether there’s od-

our source, such as

furniture and cigare-

tte, etc. 

Phenomenon

Odours are 

emitted

Check items

Whether it's interfered 

severely (such as sta-

tic electricity, stable 

voltage?)  

Solution

Pull out the plug.

Reinsert the plug after 

about 3min, and then

turn on the unit again.  

Set tempe-
rature can’t
be adjusted 

Set temperature 

range: 16

~30

.

Signal receiving 

range is 8m. 

Whether there are 

obstacles? 

Indoor unit 
can’t receive 
remote co-
ntroller’s si-
gnal or remote 
controller has 
no action.

Cooling
(heating)
effect is 
not good. 

Set temperature is 

in proper range? 

Door and window 

are open? 

Close door and 

window.

Air conditi-
oner operates 
abnormally

Outdoor unit  

has vapor

Heating mode is 

turned on? 

Fluorescent lamp in 

room? 

“Water 
flowing”
noise

Air conditioner is 

turned on or turned 

off just now? 

Air inlet or air outlet 

of indoor unit is 

blocked? 

After reaching to set

temperature, indoor  

unit will stop blowing

out air. 

No air 
emitted 
from indoor 
unit  

Cracking
noise 

Air conditioner is 

turned on or turned 

off just now?

Wait until power 

recovery.

Air 
conditioner 
can’t operate 

■ 

■ 

Mist is emi-
tted from
indoor unit’s
air outlet 

professionals.

eliminated,  please contact

 

local dealer or qualified

 

maintenance. If the malfunction  

 

still can’t be

 

P leas e   ch e c k   below   it e ms before asking for

 

General phenomenon analysis

F

irst 

B

efore 

M

aintenance

Check the 

F

ollo

w

in

g

 Items 

Summary of Contents for Primus Gold KSG-IWF-10WFY-8K1M32

Page 1: ...Original Instructions Split Air Conditioner KSG IWF 30WFY 8K1M32 KSG IWF 25WFY 8K1M32 KSG IWF 20WFY 8K1M32 KSG IWF 15WFY 8K1M32 KSG IWF 10WFY 8K1M32 MODELS ...

Page 2: ...KSG IWF 30WFY 8K1M32 KSG IWF 25WFY 8K1M32 KSG IWF 20WFY 8K1M32 KSG IWF 15WFY 8K1M32 KSG IWF 10WFY 8K1M32 MODELS ...

Page 3: ...ion of outdoor unit Test and operation Operation and introduction of remote controller Configuration of connection pipe Thank products please refer to actual Actual product may be NOTE you have lost the Owner s Manual before operation and retain it Please read this Owner s Manual you for choosing our graphics different from www kolinphil com ph for an electronic version please visit for future ref...

Page 4: ...ns This symbol indicates the possibility of death or serious injury This symbol indicates the possibility of injury or damage to property Indicates important but not hazard related information used to indicate risk of property damage Children should be supervised to ensure that they do not play with the appliance use of the appliance by a person responsible for their safety knowledge unless they h...

Page 5: ...e the sustainable reuse of material resources To return your used device nce by a person responsible for their safety Children should be supervised to ensure that th ey do not play with the appliance Hereby our company declare that this Air Condi tioner is in compliance with the essential require ment and other relevant provisions of RE Directive 2014 53 EU A copy of the full DoC is attached Wirel...

Page 6: ...nt If you should cut or weld the refrigerant system pipes in the process of maintaining please foll ow the steps as below c Vacuuming d e Cutting or welding Clean it with N2 gas f Carry back to the service spot for welding Filling the refrigerant The refrigerant should be recycled into the sp ecialized storage tank Make sure that there isn t any naked flame ne ar the outlet of the vacuum pump and ...

Page 7: ...itioner Unstable power supply or incorrect wiring may result in electric shock fire haza rd or malfunction Please install proper power supply cables before using the air conditioner short circuit unit from overloading and function It can protect the buckleand heating buckle included with magnet breaker should be cted in fixed wiring Circuit all poles should be conne paration of at least 3mm in swi...

Page 8: ...for a new one The appliance must be po sitioned so that the plug is accessible For the air conditioner with plug the plug should be re achable after finishing in stallation tube away from the copper the interconnection cable higher so please keep gerant circuit will get The temperature of refri may cause electric shock ed effectively otherwise it sure it is always ground fessional Please make ound...

Page 9: ...cturer its ser vice agent or similarly qua lified persons in order to avoid a hazard Do not connect air condi injury or damage It may cause personal into the air inlet or outlet fingers or any objects Do not extend your avoid injury not touch the fins to After removing the filter do air conditioner when you need to repair Please contact your dealer damage on the unit personal injury or er by yours...

Page 10: ...mote controller otherwise Do not spill water on the re and Maintenance Operation Circuit breaker trips off during operation There s abnormal sound or damaged Power cord is overheating service service center for a your nearest authorized contact your dealer or immediately and then disconnect the power the air conditioner and occurs please turn off When below phenomenon age or personal injury object...

Page 11: ...d disconnect the power before cleaning the air conditioner to av oid electric shock Do not wash the air conditioner with water to avoid electric shock Do not use volatile liquid to clean the air conditioner Do not use liquid or corrosive detergent to clean the appliance and do not splash water or other liquid onto it otherwise it may damage the plastic components even cause electric shock contact ...

Page 12: ...here s abnormal sound during operation Air switch trips off frequently Air conditioner gives off burning smell Indoor unit is leaking Air switch trips off or fuse is burnt out Ask professional to replace airswitchorfuse Wiring has malfunc tion Ask professional to replace it Unit has restarted immediately after stopping operation Wait for 3min and then turn on the unit again Do not repair or refit ...

Page 13: ...nnections between the indoor and outdoor units Firmly clamp the wires so that their te rminals receive no external stresses NOTICE When installing or moving this unit do not charge the refrigerant which is not comply with that on the nameplate or unqualified refrigerant Otherwise it may cause abnormal operation wrong action mechanical malfunction or even serious safety accident Prohibit installing...

Page 14: ...l pole disconnection switch having a co ntact separation of at least 3mm in all poles should be connected in fixed wiring grounding wire which can t be used for other purposes The grounding resistance should comply with The place near coast area The place with oil or fumes in the air The place with sulfureted gas Other places with special circumstances The appliance shall not be installed in the f...

Page 15: ...vention a e m y t e f a s t n a v e l e r e k a t d n a sures when opening the hole The pipe can be led out in the direction of right Please refer to the actual circumstances for the number of screws and the position of screws Choose the position of piping hole according Adjust the torque force by referring to the wrench on the union nut Tighten the union nut with torque wrench to the direction of...

Page 16: ...que N m NOTE Add insulating pipe in the indoor drain hose in order to prevent condensation The plastic expansion particles are not provided All wires of indoor unit and outdoor unit should be If the length of power connection wire is insufficient For the air conditioner with plug the plug should be NOTICE connected by a professional Make the power connection wire go through the cable cross hole at...

Page 17: ... hole Hang the indoor unit on the wall mounting frame Stuff the gap between pipes and wall hole with sealing gum Fix the wall pipe Check if the indoor unit is installed firmly and closed to the wall Remove the wire clip connect the power conn ection wire to the wiring terminal according to the color tighten the screw and then fix the po wer connection wire with wire clip blue black brown Outdoor u...

Page 18: ...r unit Pretighten the union nut with hand Connect the drain hose into the drain vent Select installation location according to the house structure As for the shape of drainage joint please refer to the current product Do not install the drainage joint in the severe cold area Otherwise it will be frosted and then cause malfunction Fix the support of outdoor unit on the sele cted location with expan...

Page 19: ...l wire with wire clip only for cooling and h eating unit Step 6 Neaten the pipes 1 U shaped curve drain hose NOTICE NOTICE NOTICE Tighten the union nut with torque wrench by referring to the sheet below The wiring board is for reference only please refer to the actual one The pipes should be placed along the wall bent If the outdoor unit is higher than the wall hole reasonably and hidden possibly ...

Page 20: ...ing to the following requirement after finishing installation Possible malfunction The unit may drop shake or emit noise Connect the charging hose of piezometer to the Is water drained well It may cause condensation and water dripping Items to be checked Has the unit been installed firmly Have you done the refri gerant leakage test It may cause malfunction or damage the parts Is electric wiring an...

Page 21: ...ifferent from above graphics please refer to actual product Temp indicator Power indicator NOTE aux button filter air inlet panel horizontal louver air outlet If remote controller is lost or damaged please use aux button to turn on or turn off the air conditioner The operation in details is as below As shown in the figure open panel and press aux button to turn off the air conditioner When the air...

Page 22: ...emp Outdoor ambient temp temp Indoor ambient Clock Operation mode Set time TIMER ON TIMER OFF Turbo mode Send signal Auto mode Cool mode Temp Dry mode Fan mode Heat mode display type I feel Set fan speed Buttons on remote controller Introduction for icons on display screen Operation and introduction of remote controller TURBO FAN MODE ON OFF I FEEL T ON T OFF TEMP CLOCK LIGHT WiFi SLEEP ...

Page 23: ...l give out a di sound which means the signal has been sent to the air conditioner When selecting auto mode air conditioner will operate automatically according to ex factory setting Set temperature can t be adjusted and will not be displayed as well Press FAN button can adjust fan speed Press button can adjust fan blowing angle After selecting cool mode air conditioner will operate under cool mode...

Page 24: ...le When reaching your required angle release the button no display horizontal louvers stops at current position TURBO T ON T OFF NOTE NOTE T ON button T ON button can set the time for timer on After pressing this button icon disappears and the word ON on remote controller blinks Press or button to adjust T ON setting After each pressing or button T ON setting will increase or decrease 1min Hold or...

Page 25: ...he controller and the unit will automatically adjust the indoor temperature according to the detected tempera ture Press this button again to close I FEEL func tion and will disappear SLEEP WiFi CLOCK LIGHT NOTE NOTE NOTE NOTE T OFF word OFF will stop blinking icon resumes displaying Cancel T OFF Under the condition that T OFF is started up press T OFF button to cancel it Press this button to turn...

Page 26: ...on will cancel energy saving function If sleep function has been set under cooling mode start up the ener gy saving function will cancel sleep function Under OFF status press and MODE buttons simultaneously to switch temperature display between C and F Under cooling mode press TEMP and CLOCK buttons simultaneously to start up or turn off ener gy saving function When energy saving function is start...

Page 27: ...ong time please take out the batteries If the display on remote controller is fuzzy or there s no display please replace batteries The auto clean function can only work under normal ambient temperature If the room is dusty clean it once a month if not clean it once every three months After the auto clean function is turned on you can leave the room When auto clean is finished the air conditioner w...

Page 28: ...m and 8m the min length of con nection pipe is 3m Max length of connection pipe is shown as below 4 1 2 The calculation method of additional refrigerant oil and refrigerant charging amount after prolong ing connection pipe After the length of connection pipe is prolonged for 10m at the basis of standard length you should add 5ml of refrigerant oil for each additional 5m of connection pipe The calc...

Page 29: ...al Outdoor side DB WB C Maximum cooling NOTE hard mold NOTICE Outer diameter mm Φ6 6 35 1 4 Φ9 9 52 3 8 Φ12 12 7 1 2 ture for cooling only unit is 18 C 43 C Φ15 8 16 5 8 Maximum heating B Remove the burrs Remove the burrs with shaper and prevent the D Put on the union nut pipe and outdoor valve install the union nut on the pipe E Expand the port Remove the union nut on the indoor connection Check ...

Page 30: ...o as to minimise the risk of a flammable gas vapour being present while the work is being performed General work area All maintenance staff and others working in the local area shall be instructed on the nature of workspace shall be sectioned off Ensure that the conditions within the area have been made safe by control of flammable material Checking for presence of refrigerant The area shall be chec...

Page 31: ...sed the secondary circuit shall be checked for the presence of refrigerant Marking to the equipment continues to be visible and legible Markings and signs that are illegible shall be corrected Refrigeration pipe or components are installed in a position where they are unlikely to be exposed to any substance which may corrode refrigerant containing components unless the components are constructed o...

Page 32: ... only with parts specified by the manufacturer Other parts may result in the ignition of refrigerant in the atmosphere from a leak 9 Cabling Check that cabling will not be subject to wear corrosion excessive pressure SAFETY OPERATION OF FLAMMABLE REFRIGERANT extinguished If a leakage of refrigerant is found which requires brazing all of the vibration sharp edges or any other adverse environmental e...

Page 33: ...s operation is absolutely vital if brazing operations on the pipe work are to take place Ensure that the outlet for the vacuum pump is not close to any ignition sources and there is ventilation available 13 Charging procedures In addition to conventional charging procedures the following requirements shall be followed Ensure that contamination of different refrigerants does not occur when using ch...

Page 34: ...nt The label shall be dated and signed Ensure that here are labels on the equipment stating the equipment contains flammable refrigerant 16 Recovery When removing refrigerant from a system either for servicing or decommissioning it is recommended good practice that all refrigerants are removed safely When transferring refrigerant into cylinders ensure that only appropriate refrigerant recovery cyli...

Page 35: ...or oils are to be removed ensure that they have been evacuated to an acceptable level to make certain that flammable refrigerant does not remain within the lubricant The evacuation process shall be carried out prior to returning the compressor to the suppliers Only electric heating to the compressor body shall be employed to accelerate this process When oil is drained from a system it shall be carr...

Page 36: ...82 227 7063 Iloilo Door 4 TDK Realty Development Corporation Building South Fundedor St Barangay Fundedor Molo Iloilo City 033 336 1970 Pampanga Mexico Gold Commercial and Residential Building Jose Abad Avenue Lagundi Mexico Pampanga 045 455 2934 OFFICE Kolin Building 1854 Sta Rita St Guadalupe Nuevo Makati City Service Hotline 02 8852 6868 PLANT Block 3 Lot 5 Main Drive First Cavite Industrial Es...

Reviews: