Owner’s Manual
6HK13BEH0
4.
MODE
- Choose cooling, heating or auto by pressing this button. When all lamps are off, it is blower mode so only
fan operates without operating compressor.
- When AUTO lamp is on, it activates cooling or heating automatically according to TARGET TEMP. It
activates cooling when TARGET TEMP is lower than CURRENT TEMP and will change to activate heating
when CURRENT TEMP reach over the TARGET TEMP by 6°F( 3°C) and change to activate cooling when
CURRENT TEMP reach over the TARGET TEMP by 6°F( 3°C).
5.
UP/DOWN BUTTONS
- Change TARGET TEMP value by +/-1.
6.
ALARM
- ALARM indicator lights (blinks) and indicates abnormal system operation. If ALARM occurs, compressor
stops. System operation stops when ALARM light is activated (blinks) longer than 3 minutes.
7.
CURRENT TEMP
- When IN lamp is on in TEMP SELECT, it displays current room temperature.
- When OUT lamp is on in TEMP SELECT, it displays outlet (cool/hot air) temperature.
- Initial unit is °F. In order to change from °F to °C, press POWER BUTTON and MODE BUTTON together for
2 seconds. Choose 7 by pressing UP/DOWN BUTTON. Choose 0 by pressing UP/DOWN BUTTON. Press
MODE BUTTON for 2 seconds then figure will change to °C
8.
TARGET TEMP
- Displays the unit set temperature.
- When OUT lamp is on in TEMP SELECT, always set TARGET TEMP value 32°F (0°C) for COOL mode and
122°F (50°C) for HEAT mode.
- When IN lamp is on in TEMP SELECT, recommendable TARGET TEMP is between 64°F and 113°F
(18°C and 45°C) for both COOL mode and HEAT mode. Recommendable TARGET TEMP for Auto mode is
between 70°F and 113°F (21°C and 45°C)
9.
EVAP FAN STEP
- Lamp(s) is(are) on according to evap fan speed. 1 lamp is on when 1 step and 2 lamps are on when 2 step
… 6 lamps are on when 6 step.
OFF-TIMER
-Enter to timer setting mode by pressing FAN SPEED BUTTON and TEMP SELECT BUTTON together for 2
seconds.
- Press UP/DOWN BUTTON to set the timer until it shows the figure you want to set. Setting range is
between 30 minutes and 12 hours.
- If you press MODE BUTTON for 2 seconds, the figure will be memorized and the compressor will stop after
the time set.
- Display will show CURRENT TEMP (for 5 seconds) and remaining time (for 2 seconds) in turn repeatedly.
AUTO RESTART
- If the unit goes off due to an electrical interruption, the unit will automatically restart when the power
resume.