Thank you for selecting this Koldwave Portable Heat pump. It provides you with spot cooling/heating for large 

areas where cooling/heating of an entire area is not practical or possible. Please read this manual before 

installing the 6HK13BEH0 as it provides important information that should be followed during installation and 

maintenance of the Portable Heat pump, allowing you to correctly set up your system for the maximum safety 

and performance. Included is information on customer support and service, if it is required. If you experience 

a problem with the unit, please refer to the Troubleshooting section in this manual to correct the problem. If the 

problem is not corrected, please collect information so that the Technical Support personnel can more effectively 

assist you.

Model No.

Weight (Net / Gross) Lbs (kg)

Condensate Tank

Gallons (Liters)

Setting Temperature

(In temp mode) °F (°C)

6HK13BEH0

190 / 196 lbs. (86 / 89 kg)

3.17 (12)

Cooling 64~113 (18~45)

Heating 56~80 (12~27)

Model No.

Application Area

(Room cool mode) ft² (m²)

Refrigerant

Type / oz (g)

Design Pressure - Hi/Low Psig

6HK13BEH0

376 (35)

R-410A /

52.2 (1,480)

450 / 250

Model No.

Wheels

pcs / diameter

Hot Air Duct Diameter

In. (mm)

Maximum Duct Length ft (m)

6HK13BEH0

4 / 76mm

12 (300)

50 (15)

Safety Devices

Compressor overload protector, Anti-freezing thermister, Full drain tank switch, Automatic restart (Power interruption), 

Compressor time delay program, High pressure sensor, Low pressure sensor.

Features

Temperature control, Self-diagnostic function, Six speed fan, Optional drain pump kit, Washable filters, °F (°C) display,

Off-timer, Auto fan speed option.

Summary of Contents for 6HK13BEH0

Page 1: ...y showing operating modes room and set temperatures and faults If an abnormal operation occurs a visual display of the fault is shown Caster wheels are included for easy portability Suitable applicati...

Page 2: ...blem is not corrected please collect information so that the Technical Support personnel can more effectively assist you Model No Weight Net Gross Lbs kg Condensate Tank Gallons Liters Setting Tempera...

Page 3: ...p hands 12 DO NOT allow chemical substances to come into contact with the unit 13 DO NOT operate the unit in the presence of flammable substances or vapors such as alcohols pesticides gasoline etc DO...

Page 4: ...d 22 Only use in the upright position on an even flat surface Unit must be positioned at least 24 inches 60 cm from the nearest object in any direction 23 Stop operation immediately if abnormal noise...

Page 5: ...ith the top fan exhaust flange to install the top fan exhaust flange on the unit as shown in Figure 6 TOP FAN EXHAUST FLANGE Figure 6 Figure 7 Figure 8 A B C Condenser plenum can be purchased separate...

Page 6: ...caster brakes to the locked position PLUGGING IN THE UNIT Check the prongs and surface of the power cord plug for dust dirt If dust and or dirt are present wipe off with a clean dry cloth Check the p...

Page 7: ...After setting the target temperature press TEMP SELECT BUTTON for 2 seconds and SET lamp will be off and setting temperature will be memorized 7 6HK13BEHO Owner s Manual Oper on CONTROL PANEL 1 POWER...

Page 8: ...ose 7 by pressing UP DOWN BUTTON Choose 0 by pressing UP DOWN BUTTON Press MODE BUTTON for 2 seconds then figure will change to C 8 TARGET TEMP Displays the unit set temperature When OUT lamp is on in...

Page 9: ...purchase 9 Maintenance FILTER CLEANING See Figures 10 and 11 There are two filters in the unit The evaporator filter is located at the front of the unit The condenser filter is located at the back of...

Page 10: ...3 minutes the evaporator fan also stops The fault must be r fied before the unit can resume normal oper on There are two springs on the rear of condensate water tank guide 1 Release the screw on the...

Page 11: ...11 Owner s Manual 6HK13BEH0 11 6HK13BEHO Owner s Manual Table 1 1 Alarm Codes Table 1 1 Alarm Codes...

Page 12: ...12 Owner s Manual 6HK13BEH0 12 6HK13BEHO Owner s Manual Table 1 2 Alarm Codes Table 1 2 Alarm Codes...

Page 13: ...13 Owner s Manual 6HK13BEH0 Wiring Diagram 6HK13BEHO Owner s Manual Wiring Diagram Figure 13 6HK13BEHO...

Page 14: ...Ambient air cannot be properly cooled if the filter is dirty and not regularly cleaned 1 Clean the filter 2 Compressor will not work if the unit is turned off and on quickly 2 Wait 2 minutes a er uni...

Page 15: ...tor Fan KWPHFANE 03 Condenser Fan KWPHFANC 03 Cap Evaporator Motor KWPHCAPM 03E Cap Condenser Motor KWPHCAPM 03C HP Sensor KWPHHPS 01 LP Sensor KWPHLPS 01 Compressor KWPHCOMP 03 Comp Cap KWPHCAPC 03 T...

Page 16: ...lacement of all parts hereunder shall not operate to extend the original warranty period as to any part including replacement parts supplied hereunder THE ABOVE WARRANTY HEREWITH SET FORTH IS IN LIEU...

Reviews: