background image

5

Owner’s Manual

6HK13BEH0

Assembly (6HK13BEH0)

5

6HK13BEHO

Owner’s Manual

Assembly (6HK13BEHO)

Front and Right Side View

Display / Control board

Top fan exhaust flange

Evaporator / filter

Guide bar for condensate water tank

Condensate water tank (Water level is

sensed, and the unit opera on is stopped

when tank is full. An alarm will be

displayed. Empty the tank and replace to

resume opera on)

1. Take out the cord holder from

    the accessory box.

2. Place the cord holder on the

    back side of the unit

3. Use screws (enclosed inside

    of accessory box with cord holder)

    to install the cord holder on the

e 4.

POWER CORD HOLDER

DISCHARGE DUCTS/SUPPLY AIR DUCT

Figure 3

Figure 2

Figure 4

Figure 5

Power cord holder
Caster

Electrical access panel

Condenser / filter

1. Remove the top fan exhaust

    flange from carton.

2. Place the top fan exhaust flange

    on the top of  the unit.

3. Use screws (enclosed inside

    of box with the top fan exhaust

    flange) to install the top fan

    exhaust flange on the unit

    as shown in Figure 6.

TOP FAN EXHAUST FLANGE

Figure 6

Figure 7

Figure 8

A

B C

Condenser plenum can be purchased separately. Condenser plenum

fits over the condenser to duct condenser air to the unit to improve 

cooling efficiency.

1. Remove the Filter("A")

2. Check the Filter("C") is inserted properly in Condenser plenum("B")

3. Install "B" which contains "C" by using driver with enclosed

     bolts(6EA) as Figure 8.

CONDENSER PLENUM 

Component parts

1. Remove cool air outlet hose(s)   

    from carton.

2. Place the cool air outlet hose(s)  

    on the front top of the unit

3. Use screws (enclosed inside of box  

    with cool air outlet hose(s) to 

    install the cool air outlet hose(s) on 

    the unit as shown in Figure 5.

EVAPORATOR PLENUM 

An evaporator plenum can be purchased 

separately. Plenum fits over the evaporator 

to duct evaporator air to the unit to 

improve cooling efficiency.

1. Remove the evaporator cover from the 

     unit.

2. Remove the filter from the evaporator 

     cover and put it into the plenum.

3. Install the plenum in front of the 

     evaporator.

Summary of Contents for 6HK13BEH0

Page 1: ...y showing operating modes room and set temperatures and faults If an abnormal operation occurs a visual display of the fault is shown Caster wheels are included for easy portability Suitable applicati...

Page 2: ...blem is not corrected please collect information so that the Technical Support personnel can more effectively assist you Model No Weight Net Gross Lbs kg Condensate Tank Gallons Liters Setting Tempera...

Page 3: ...p hands 12 DO NOT allow chemical substances to come into contact with the unit 13 DO NOT operate the unit in the presence of flammable substances or vapors such as alcohols pesticides gasoline etc DO...

Page 4: ...d 22 Only use in the upright position on an even flat surface Unit must be positioned at least 24 inches 60 cm from the nearest object in any direction 23 Stop operation immediately if abnormal noise...

Page 5: ...ith the top fan exhaust flange to install the top fan exhaust flange on the unit as shown in Figure 6 TOP FAN EXHAUST FLANGE Figure 6 Figure 7 Figure 8 A B C Condenser plenum can be purchased separate...

Page 6: ...caster brakes to the locked position PLUGGING IN THE UNIT Check the prongs and surface of the power cord plug for dust dirt If dust and or dirt are present wipe off with a clean dry cloth Check the p...

Page 7: ...After setting the target temperature press TEMP SELECT BUTTON for 2 seconds and SET lamp will be off and setting temperature will be memorized 7 6HK13BEHO Owner s Manual Oper on CONTROL PANEL 1 POWER...

Page 8: ...ose 7 by pressing UP DOWN BUTTON Choose 0 by pressing UP DOWN BUTTON Press MODE BUTTON for 2 seconds then figure will change to C 8 TARGET TEMP Displays the unit set temperature When OUT lamp is on in...

Page 9: ...purchase 9 Maintenance FILTER CLEANING See Figures 10 and 11 There are two filters in the unit The evaporator filter is located at the front of the unit The condenser filter is located at the back of...

Page 10: ...3 minutes the evaporator fan also stops The fault must be r fied before the unit can resume normal oper on There are two springs on the rear of condensate water tank guide 1 Release the screw on the...

Page 11: ...11 Owner s Manual 6HK13BEH0 11 6HK13BEHO Owner s Manual Table 1 1 Alarm Codes Table 1 1 Alarm Codes...

Page 12: ...12 Owner s Manual 6HK13BEH0 12 6HK13BEHO Owner s Manual Table 1 2 Alarm Codes Table 1 2 Alarm Codes...

Page 13: ...13 Owner s Manual 6HK13BEH0 Wiring Diagram 6HK13BEHO Owner s Manual Wiring Diagram Figure 13 6HK13BEHO...

Page 14: ...Ambient air cannot be properly cooled if the filter is dirty and not regularly cleaned 1 Clean the filter 2 Compressor will not work if the unit is turned off and on quickly 2 Wait 2 minutes a er uni...

Page 15: ...tor Fan KWPHFANE 03 Condenser Fan KWPHFANC 03 Cap Evaporator Motor KWPHCAPM 03E Cap Condenser Motor KWPHCAPM 03C HP Sensor KWPHHPS 01 LP Sensor KWPHLPS 01 Compressor KWPHCOMP 03 Comp Cap KWPHCAPC 03 T...

Page 16: ...lacement of all parts hereunder shall not operate to extend the original warranty period as to any part including replacement parts supplied hereunder THE ABOVE WARRANTY HEREWITH SET FORTH IS IN LIEU...