D. CONNECT CONTROL BOX - 230V, 50 HZ
Connect service to the field wiring compartment of the
control box. The 50 Hz model control box contains blue
and brown wires and earth lug.
A 230V, 15A, 50 Hz dedicated circuit is required. Provide
an Earth Leakage Circuit Breaker.
Provide a separate equipment earthing conductor for the
inside earth lug. The earthing conductor must not be
connected to any current carrying conductor. Follow
local electrical codes. A 230 V, 15A, 50 Hz separate
circuit is required.
Earth
(Ground) Lug
Earth
(Ground)
Neutral
Earthing Lug (for
bonding in accor-
dance with national
and local codes)
Blue
(Neutral)
Brown
(Phase)
Wire Connectors
Phase (Line)
10. WATER TEST WHIRLPOOL & ELECTRONICS
Check all electrical connections. Make sure both
connections to the pump are securely tightened.
Fill bath to a level at least 2” above the top of the highest
jet.
Operate whirlpool for 5 minutes and check all whirlpool
harness (piping) connections for leaks.
For additional information on whirlpool operation, see
Whirlpool Start-Up Instructions on page 14.
11. COMPLETE FINISH WALL
CAUTION: Risk of product damage. Do not
support the weight of the whirlpool by the rim.
Protect whirlpool surface. Make sure the vinyl bead is
attached securely to the sides being built into the wall.
Cover framing and walls with gypsum wallboard.
Caulk with a water resistant sealer where gypsum
wallboard meets with bath bead. Install wall covering so
it is 1/16” above enameled surface. Caulk along area
where wall covering overlaps bath bead with a water
resistant sealer. Install finished wall material to subwall.
Seal joints under bath rim and finished wall.
Install finished floor. Caulk along bottom edge of apron
with a water-resistant sealer.
Gypsum Wallboard Subwall
Finished Wall Material
Water-Resistant Sealant
2 x 4 Studding
Vinyl Tiling-In Bead
Bath Rim