9.  FIELD WIRE ELECTRONICS

A.  IDENTIFY ELECTRICAL REQUIREMENTS

The model number is printed on a plate at the pump end
of the module.

The model number identifies electrical rating. Electrical
connections for each model vary.

S

K-852-V-AB:

60 Hz

(Follow Step B. below.)

S

K-852-JA-AA:

50 Hz

(Follow Steps C. and D. below.)

See Electrical Requirements section on page 6 of
Product Requirements.

B. WIRING INFORMATION - 120V, 60 HZ

(EXCLUDING -J1 MODELS)

WARNING: Risk of electrical shock.  To reduce
the risk of electric shock, connect only to a properly
grounded, grounding-type receptacle, protected
by a Ground-Fault Circuit-Interrupter (GFCI). Do
not remove the plug’s grounding pin. Do not use a
grounding adapter.

Your Kohler Whirlpool bath is equipped with a cord and
plug. All wiring of the pump and control has been
completed at the factory. A licensed electrician must
install a GFCI protected, 120 Volt, 15 Amp, grounded
outlet. Your whirlpool may then be plugged into this
outlet. No other load should be on this circuit.

C.   FIELD WIRING  CONTROL BOX

COMPARTMENT - 230V, 50 HZ

WARNING: Risk of electrical shock. Make sure
the power has been disconnected before
performing the following procedures. Refer to
Important Safety Instructions located on page 2.

CAUTION: Risk of electrical shock. All services
must have an Earth Leakage Circuit Breaker
(ELCB) which will provide additional protection
against line-to-ground shock hazard. A separate
service is required for the whirlpool.

The whirlpool controls and system have been prewired
at the factory. A licensed electrician should make a
routine service connection to the field wiring
compartment of the control box containing blue and
brown wires and earth lug.

* For bonding in accordance with National and Local
Codes.

Field Wiring
Compartment

Bonding
(Earthing) Lug*

Air
Actuator

Air
Actuator
Tube

Pump

Control
Box

Summary of Contents for Tea-For-Two K-852-JA-AA

Page 1: ...R Tea For Two Whirlpool Baths K 852 V AB K 852 JA AA 111889 CA 1093 Copyright E1993 Kohler Co...

Page 2: ...cted by a qualified licensed electrician For J1 and JA models only A green colored terminal or a wire connector marked G GR GROUND or Grounding is provided within the terminal compartment To reduce th...

Page 3: ...60 Hz 11 Field Wiring Control Box Compartment 230 V 50 Hz 11 Connect Control Box 230 V 50 Hz 12 WATER TEST WHIRLPOOL ELECTRONICS 12 COMPLETE FINISH WALL 12 COMPLETE INSTALLATION 13 Install Handles an...

Page 4: ...required protected with Class A Ground Fault Circuit Interrupter 60 Hz or ELCB 50 Hz Pump control 120 V 15 A 60 Hz or 230 V 15 A 50 Hz C PRODUCT INFORMATION Fixture basin area top area weight Bathing...

Page 5: ...lation including the following Product Requirements NOTICE Follow all local plumbing and electrical codes B FACTORY ASSEMBLED FEATURES K 852 V Factory installed components include pump with integral t...

Page 6: ...tened D CONNECTIONS AND SERVICE ACCESS Before installation ensure proper access to the final connections NOTICE Provide unrestricted service access to the pump An access panel 20 W x 15 H minimum must...

Page 7: ...sealant C CLEARANCE REQUIREMENTS Check roughing in and room dimensions in order to provide adequate available space for the bath unit D NEW OR REPLACEMENT INSTALLATION REQUIREMENTS This bath unit can...

Page 8: ...educe the risk of water damage C STUD POCKET PREPARATION Construct a recess designed for your particular installation Framing is of 2 x 4 construction When constructing framing allow for thickness of...

Page 9: ...s 6 BEFORE INSTALLING UNIT A TILING IN BEAD INSTALLATION Before setting bath an optional tiling in bead is recommended to be applied to whatever side of the bath contacts the wall Refer to Ordering In...

Page 10: ...ommodate the piping Metal Shims Metal Shim B INSTALL PLUMBING CAUTION Risk of damage to whirlpool bottom and subfloor Ensure watertight seal on bath drain connections 1 When whirlpool is securely posi...

Page 11: ...mpleted at the factory A licensed electrician must install a GFCI protected 120 Volt 15 Amp grounded outlet Your whirlpool may then be plugged into this outlet No other load should be on this circuit...

Page 12: ...to a level at least 2 above the top of the highest jet Operate whirlpool for 5 minutes and check all whirlpool harness piping connections for leaks For additional information on whirlpool operation s...

Page 13: ...r installation do not use abrasive cleaners as they may scratch and dull the module surface Use warm water and one of the liquid detergents to clean the surface Stubborn stains paint or tar can be rem...

Page 14: ...the top of the highest jet Water temperature in the whirlpool should not exceed 104_F 40_C Bath Wall 2 Minimum Water Line Jet Trim B OPERATING SEQUENCE Refer to chart for proper operating sequence 1...

Page 15: ...unterclockwise to open are not functioning B Trim kit installed incorrectly B Reinstall trim kit checking for damage to O Ring C Jets are blocked C Remove blockage 3 Motor turns water is pumping but A...

Page 16: ...R 111889 CA 1093 Kohler Co Kohler WI...

Reviews: