background image

N. Install the Seat

Position a bolt and washer through each of the three holes in
the toilet seat hinge.

Position the gasket on the bolts from the underside of the
hinge.

Place a plastic tapered bushing, tapered-side-down, on each
of the bolts.

Place an expansion sleeve on each bolt.

Thread a brass tapered bushing, tapered-side-up, onto each
bolt. Do not tighten at this time.

Position the seat on the toilet and align the bolts with the toilet
seat mounting holes.

Insert the bolts and sleeves into the holes.

Use a flat blade screwdriver to thread the bolts until they are
snug, but do not fully tighten at this time.

Lower the seat and check seat alignment.

Align the seat on the toilet and then carefully raise the seat to
expose the bolts.

Tighten the bolts. Do not overtighten.

Position the tab on the hinge cover with the slot in the hinge
assembly and snap the hinge cover into place.

With the seat raised, gently push the seat cover forward. The
seat and seat cover should close Slowly.

N.

M. Secure the Vitreous Shell

CAUTION: Risk of product
damage.

Do not overtighten the

screws when tightening. The
vitreous shell may chip or break
if the screws are overtightened.

Insert a screw through both grommets.

Insert a screw in both of the provided
holes and tighten. Do not overtighten.

Place a cap over each screw. The
caps should be flush with the exterior
of the shell.

M.

Screw

Cap

Grommet

Fig.#12

12

Fig.#13

13

Hinge Cover

Hinge Cover Tab

Hinge Slot

Cover/Seat

Bolt

Washer

Plastic Tapered Bushing

Brass Tapered Bushing

Toilet

Hinge

Gasket

Expansion Sleeve

Toilet Seat Mounting Hole

-8-

1061926-T01-A

Summary of Contents for PURIST K-3492K

Page 1: ...G Risk of electric shock CAUTION Risk of hazardous gases NOTICE Follow all local plumbing and electrical codes NOTICE WARNING Risk of electric shock for handwire installations through floor electrical supply Disconnect power before servicing Connect only to circuits protected by Ground Fault Circuit Interrupters GFCI s or Earth Leakage Circuit Breakers ELCB s If a new toilet is not installed immed...

Page 2: ...y Stop with filter of Outlet GFCI Protected Receptacle water proof Floor Flange T Bolts T Maximum Height Both the electrical and water supplies can be installed on either the wall or the floor Follow the information for your particular installation Supply Stop 9 5 Compression Supply Hardwire Electrical Supply 19 19 70 Note Plastic Anchor Recommend use outside dia 10mm Screw Recommend use M6 screw ...

Page 3: ...unted on the wall a GFCI or ELCB protected and water proof receptacle is required Follow the dimensional information exactly when installing a hardwire electrical supply B GFCI ELCB GFCI ELCB A To Remove Existing Toilet Turn off the water supply Flush the toilet and use a sponge to remove the remaining water from the tank and bowl Disconnect the supply shut off valve if present and remove the old ...

Page 4: ...on any part of the tank assembly other than the cylinder Damage may occur Press down on the cylinder where the gasket was mounted Do not press anywhere else on the tank Assembly Do not rock or lift the tank after placement The seal created by the wax ring may be broken resulting in leaking Replace the gasket Position the loose end of the refill tube in the outlet ring CAUTION Risk of product damag...

Page 5: ... Base of Tank Unit Fig 6 6 H Check the Waterline NOTE IMPORTANT The waterline is a notch in the inside of the tank marked with a label Turn on the water supply Open the motorized valve by sliding the lever back into the open position Verify the inlet valve is set to the correct waterline Adjust if needed To adjust the inlet valve use a flathead screwdriver to gently turn the adjustment rod counter...

Page 6: ...r lifting technique when handling the vitreous shell Do not set the shell down hard Gently lift and move the shell if it is not placed correctly If handled harshly the shell may chip or break Carefully pick up the vitreous shell and place it over the tank Make sure the trapway seats fully in the outlet gasket If the vitreous shell does not sit evenly on the floor the trapway is not properly seated...

Page 7: ...ubleshooting chart if the toilet does not function properly L K Connect the Wiring WARNING Risk of personal injury Make sure the plug if plug in connection is used and receptacle are dry If any moisture is present allow the area to dry before plugging the unit in If plug in connection is desired plug the pump in Connect the refill tube Connect the wiring harness Connect the level switch K Level Sw...

Page 8: ...arefully raise the seat to expose the bolts Tighten the bolts Do not overtighten Position the tab on the hinge cover with the slot in the hinge assembly and snap the hinge cover into place With the seat raised gently push the seat cover forward The seat and seat cover should close Slowly N M Secure the Vitreous Shell CAUTION Risk of product damage Do not overtighten the screws when tightening The ...

Page 9: ...fe at the spot marked on the access cover Place the access cover over the opening in the back of the toilet Caulk around the base of toilet Do not caulk the area where the access cover meets the floor Fig 14 14 Access Opening Caulk Base Of Toilet Toilet Back Do Not Caulk Base Of Access Cover Cut With Utility Knife Access Cover COMPLETE THE INSTALLATION 9 1061926 T01 A ...

Page 10: ...or ELCB is tripped C There is a problem with the pump connection D The actuation switch is not properly connected E The level switch is not properly connected F The pump assembly does not Work G The actuation assembly does not work A Check the wiring and connect the power B Reset the GFCI or ELCB if Applicable C Check the pump connection D Check the actuation switch Connection E Check the level sw...

Page 11: ...1 A A 2 A A 3 A B A B 4 A B C D A B C D 5 A B C D E F G A B C D E F G 11 1061926 T01 A ...

Page 12: ...fixtures and fittings are warranted to be free of manufacturing defects This product is warranted for one year from date of purchase Kohler China will be responsible for any problems caused by manufacturing defects provided with the invoice Kohler China will at its election repair replace or make appropriate adjustment where Kohler China inspection discloses any such defects occurring in normal us...

Page 13: ... Braided Hose 1017207 Gasket 1017206 Collar 1031167 Water Sensor 1024416 Screw 1045747 Braided Hose 1030578 Cord 38820 O Ring O 1023378 Gasket 1023378 Gasket 84678 Nut 1017874 Spray Shield 1018085 Inlet 1043213 Fill Valve 1050640 Junction Box 1034173 Cover Packet 1030800 Cable Tie 1024416 Screw 1006734 Nut 1006734 Nut 13 1023457 Wax Ring 81632 Floor Flang 1061926 T01 A ...

Page 14: ...54 Pump Flush Assembly 1022454 Priming Device 1025461 Tube 1023643 Hose Clamp 1023643 Hose Clamp 1017531 Check Valve Housing 1017532 Check Valve Housing 1017533 Washer 1017270 Tube 1017269 Tube 1023505 Clamp 1023505 Clamp 83040 Clamp 1017793 Shroud 1024416 Screw 1024417 Washer 1042615 Hold Down Kit 1042617 Panel 1022679 Seat 1042395 Bumper 1030310 Hinge Cover 1017534 Check Valve Body 1023505 Clamp...