5
114189-2-
CA
(9608)
Kohler Co., Kohler WI
2. PRODUCT NOTICES
A. INSTALLER HAZARD NOTIFICATION
DANGER: Risk of fire, electric shock, or injury
to persons. Read important safety instructions on
inside front cover of these instructions.
WARNING: Risk of electrical shock. A licensed
electrician should make all electrical connections.
WARNING: Risk of electrical shock. Connect
only to a circuit protected by a Ground-Fault
Circuit-Interrupter (GFCI).
WARNING: Risk of electrical shock. Disconnect
power before servicing.
WARNING: Risk of injury or property damage.
Please read all instructions thoroughly before
beginning installation, including the following
Product Requirements.
NOTICE: Follow all local plumbing and electrical
codes.
B. FACTORY-ASSEMBLED FEATURES
K-1355-H1, K-1356-H1: Factory installed components
include pump with integral heater, control, variable flow
valve, and switch. No installation is needed.
The whirlpool pump and piping are factory-assembled.
WARNING: Unauthorized modification may
cause unsafe operation and poor performance
of the whirlpool. Do not relocate the whirlpool
pump, or make other modifications to the whirlpool
system, as this could adversely affect the
performance and safe operation of the whirlpool.
Kohler Co. shall not be liable under its warranty or
otherwise for personal injury or damage caused by
any such unauthorized modification.
3. PRODUCT REQUIREMENTS
A. SUMMARY OF KEY REQUIREMENTS
Install unit to a level subfloor.
Provide properly dimensioned framing.
Recess installation is recommended.
B. PLUMBING SPECIFICATIONS
Confirm adequate support for the faucet; large faucets
that may be inadvertently used as a means of support
are not appropriate or safe for this installation.
C. PRODUCT INSPECTION
Carefully uncrate and inspect your product for damage.
Do not remove the spacer bar until the unit is
secured to the stud pocket.
Return whirlpool to carton during construction to prevent
damage.
NOTICE: Make sure both union connections to the
pump are securely tightened.
D. CONNECTIONS AND SERVICE ACCESS
Before installation, ensure proper access to the final
connections.
NOTICE: Provide unrestricted service access to the
pump and controls. Removable front apron provides
access to the pump and controls.
E. ELECTRICAL REQUIREMENTS
The installation must have a Class A Ground-Fault
Circuit-Interrupter (GFCI). The GFCI protects against
line-to-ground shock hazard. Use a 120 V, 20 A, 60 Hz
dedicated service for the whirlpool.