background image

17

114189-2-

CA

 (9608)

Kohler Co., Kohler WI

 18. TROUBLESHOOTING PROCEDURES

A. FLEXJET INSTALLATION 

NOTE: The Flexjet O-ring must be correctly positioned,
must be lubricated, and must be in good condition to
permit easy rotation and proper operation.

1.

Install the O-ring onto the first shoulder of the
Flexjet. Lubricate the O-ring with silicone lubricant
to prevent noisy operation of the Flexjet.

2.

Insert the Flexjet into the housing, and lightly push
and rotate the Flexjet until it snaps into position. Do
not force the Flexjet.

NOTE: When installed correctly, the Flexjet should turn
smoothly both clockwise and counterclockwise.

Flexjet Housing

O-Ring (Must
Be Lubricated)

Flexjet

Slide O-Ring

Summary of Contents for Precedence K-1355-H1

Page 1: ... Precedence Bath Whirlpools K 1355 H1 K 1356 H1 114189 2 CA 9608 Copyright 1996 Kohler Co ...

Page 2: ... other electrical equipment and exposed metal in the vicinity as needed to comply with local requirements DANGER RISK OF INJURY Hot whirlpool baths can put certain stresses on the body as do any hot bath shower sauna or steam bath Prolonged immersions in hot water may induce hyperthermia Hyperthermia occurs when the internal temperature of the body reaches a level several degrees above the normal ...

Page 3: ...Wiring Compartment H1 Models 10 Connect Compressor Box H1 Models 11 INSTALL WHIRLPOOL TRIM KIT 11 TEST DOOR SYSTEM 12 Operating Sequence 12 Troubleshoot Door System 12 WATER TEST WHIRLPOOL ELECTRONICS 13 INSTALL APRONS 13 INSTALL FINISH WALL 14 INSTALL KICK STRIP 14 CLEAN UP AFTER INSTALLATION 15 CONFIRM PROPER OPERATION 15 Start Up Whirlpool 15 Operating Sequence 16 TROUBLESHOOTING PROCEDURES 17 ...

Page 4: ... protected with Class A Ground Fault Circuit Interrupter GFCI Pump control 120 V 20 A 60 Hz C PRODUCT INFORMATION Fixture basin area top area weight Bathing well 43 x 20 52 x 25 188 lbs water depth capacity To overflow 19 1 4 80 gals Approximate measurements for comparison only Pump HP V Hz A 1 speed 2 120 60 18 5 Included Components Apron factory installed D INSTALLATION NOTES Read the entire ins...

Page 5: ...hirlpool system as this could adversely affect the performance and safe operation of the whirlpool Kohler Co shall not be liable under its warranty or otherwise for personal injury or damage caused by any such unauthorized modification 3 PRODUCT REQUIREMENTS A SUMMARY OF KEY REQUIREMENTS Install unit to a level subfloor Provide properly dimensioned framing Recess installation is recommended B PLUM...

Page 6: ...s whirlpool can be installed in new or existing bathrooms For new installations Position the plumbing according to the roughing in on Page 4 Cap the supplies and check for leaks For replacement installations Remove the old bath Remove the old wall material and remove any old floor covering from the area Remove any old plumbing that does not conform to roughing in requirements 5 SITE REQUIREMENTS A...

Page 7: ... This should be close to 60 Size the stud pocket accordingly NOTE The stud pocket must fit the width of the unit exactly The bath is shipped with a spacer bar to prevent spreading or squeezing of the door opening This would affect the proper function of the inflatable seal and door Construct a recess designed for your particular installation Install stud pocket headers Construct the required acces...

Page 8: ...ording to the drain manufacturer s instructions C PROTECT WHIRLPOOL UNIT Position a drop cloth or similar material in the bottom of the unit Be careful not to scratch the surface of the product 7 INSTALL THE WHIRLPOOL A WHIRLPOOL SET IN The pump base pan is integral to the unit If the subfloor is level no adjustments are required Set the whirlpool into place align the drain tailpiece with the trap...

Page 9: ... the nailing flange to the stud pocket header with the screws supplied with the unit After the unit is secured to the header to prevent spreading or squeezing of the walls remove the shipping spreader bar Test the operation of the door to ensure there is no binding Supplied Screws Spacer Bar E PUMP BANDING STRAP CUT NOTICE This step is necessary to make your Kohler whirlpool operate more quietly 1...

Page 10: ...Air Compressor 9 ELECTRICAL CONNECTIONS A IDENTIFY ELECTRICAL REQUIREMENTS The model number is printed on a label at the pump end of the whirlpool The label identifies electrical rating B FIELD WIRING COMPARTMENT 120 V 60 HZ H1 UL LISTED MODELS WARNING Risk of electrical shock Make sure the power has been disconnected before performing the following procedures Refer to Important Safety Instruction...

Page 11: ... 120 V 20 A dedicated circuit is required Provide a Class A Ground Fault Circuit Interrupter GFCI Provide a separate equipment grounding conductor for the inside grounding lug Ground must not be connected to any current carrying conductor Green Wire Ground Black Wire Line White Wires Neutral Ground Lug Wire Nut Bonding Lug Water Level Sensor To Pump 10 INSTALL WHIRLPOOL TRIM KIT Refer to the insta...

Page 12: ...n Suction Whirlpool Jet Water Line 2 Min B TROUBLESHOOT DOOR SYSTEM This troubleshooting guide is for general aid only A Kohler Authorized Service Representative or a qualified electrician should correct all electrical problems For warranty service contact your dealer or wholesale distributor SYMPTOMS PROBABLE CAUSES RECOMMENDED ACTION 1 Door won t close A Seal is out of track A Re insert seal B S...

Page 13: ...age 15 13 INSTALL APRONS Locate the screws removed during the whirlpool inspection This apron system is designed so the finish wall materials go over the apron columns It is also designed so the finished floor materials butt up against the pan base Slip the top of an apron up into the channel groove Tilt the apron inward Align the bottom of the apron with the pan base The apron should align with b...

Page 14: ...ant to seal the joints between the whirlpool rim and the finish wall Stud Water Resistant Wall Material Finish Wall Covering Silicone Sealant Whirlpool 15 INSTALL KICK STRIP NOTE Install kick strip after the finished flooring is installed With the paper backing still attached position the kick strip along the outline of the whirlpool base Begin at one end and peel back a few inches of the paper ba...

Page 15: ...moved by scraping with a wood edge Do not use metal scrapers wire brushes or other metal tools A powder type detergent may be used on a damp cloth to provide mild abrasive action to the residual plaster Polystyrene FRP Polystyrene 17 CONFIRM PROPER OPERATION A START UP WHIRLPOOL Refer to Important Safety Instructions on Page 2 Please perform the following so the owner can safely receive the benefi...

Page 16: ...built in heater automatically maintains the water temperature while whirlpool bathing TO METHOD OBSERVE Turn on whirlpool massage and the heater Decrease flow by pressing key increase flow by pressing key To add air and water to whirlpool action rotate the flange counterclockwise To reduce air and water rotate it clockwise Shut off whirlpool Restart whirlpool after 20 minute cycle is complete Redu...

Page 17: ... 1 Install the O ring onto the first shoulder of the Flexjet Lubricate the O ring with silicone lubricant to prevent noisy operation of the Flexjet 2 Insert the Flexjet into the housing and lightly push and rotate the Flexjet until it snaps into position Do not force the Flexjet NOTE When installed correctly the Flexjet should turn smoothly both clockwise and counterclockwise Flexjet Housing O Rin...

Page 18: ...e to O ring C Jets are blocked C Remove blockage 3 Whirlpool stops automatically A GFCI trips A Identify source of fault and correct automatically before 18 minutes B Suction blocked B Remove obstruction before 18 minutes C Jets are blocked C Remove blockage D Motor overheated and protection device activated D Check for blockage at motor vents Remove blockage and allow motor to cool Check for suct...

Page 19: ...19 114189 2 CA 9608 Kohler Co Kohler WI ...

Page 20: ... 114189 2 CA 9608 Kohler Co Kohler WI ...

Reviews: