8. COMPONENT LOCATION
Familiarize yourself with the location of all major
components before proceeding to the wiring (as
required), trim kit installation, testing, and
troubleshooting.
This unit uses a compressor assembly to inflate a seal
in the door. The door has a backup gasket on the outside
for added safety.
A bolt-type latch secures the door. It is released by the
button on top of the door. After the button is depressed,
slight pressure inward should open the door.
This unit is different from many other Kohler whirlpools
in that the power for the whirlpool pump and controls is
supplied through the compressor assembly control box.
Jet
Suction
Button
Door
Hose
Pump
Seat
Control
Switch
Inflatable
Seal
Backup
Gasket
Air Compressor
9. ELECTRICAL CONNECTIONS
A. IDENTIFY ELECTRICAL REQUIREMENTS
The model number is printed on a label at the pump end
of the whirlpool.
The label identifies electrical rating.
B. FIELD WIRING COMPARTMENT – 120 V, 60
HZ, -H1 (UL LISTED) MODELS
WARNING: Risk of electrical shock. Make sure
the power has been disconnected before
performing the following procedures. Refer to
Important Safety Instructions located on Page 2.
CAUTION: Risk of electrical shock. All services
must have a Class A Ground-Fault
Circuit-Interrupter (GFCI) which will provide
additional protection against line-to-ground shock
hazard. A dedicated service is required for the
whirlpool.
The whirlpool controls and system have been prewired
at the factory. A licensed electrician should make a
routine service connection to the compressor box
accessible through the apron.
* For bonding in accordance with national and local
codes.
Pump
Switch
Bonding
(Earthing) Lugs*
Pump
Control Box
Compressor Box