Inlet Connector
INSTALLATION
Warning!
Isolate the electrical and water supplies before installing the shower.
1.
Decide on a suitable position for the appliance (minimum distance of 200 mm
from the ceiling to allow for cover fit and removal). The position of the appliance
and the shower fittings must provide a minimum gap of 25 mm between the spill-
over level of the shower tray/bath and the handset. This is to prevent
backsiphonage
2.
Put the installation template on the wall and mark the positions of the
top two
fixing holes. Ensure that there are sufficient lengths of supply pipe and electrical
cable to reach the connection points as shown on the template.
3.
Remove the installation template and drill the
top two
fixing holes. Insert the
supplied wall plugs.
Caution!
Do not drill into cables or pipes in the wall.
4.
Thoroughly flush the supply pipe.
5.
On the shower, turn both knobs to the
full anti-clockwise position.
6.
Remove the three screws that hold the
cover on the shower and remove the
cover.
7.
Remove the service tunnel from the
shower.
8.
Determine the direction of the incoming
water supply: falling (entering the
shower from the top), or rising (entering
the shower from the bottom).
Do not
use an incoming supply
entering the shower directly from the
back. Add an elbow to the supply pipe
and connect it as a rising or falling
supply.
9.
Rotate the inlet connector to suit the
direction of the incoming water supply.
Screws
Cover
Service Tunnel
Shower
Screw