![Kohler Mira Platinum Dual Installation Manual Download Page 50](http://html.mh-extra.com/html/kohler/mira-platinum-dual/mira-platinum-dual_installation-manual_1987061050.webp)
50
1199702-W2-H
Isolate the electrical and water
supplies to the Digital Mixer Valve,
and open an outlet fitting to release
pressure and to assist the draining
of residual water.
Unscrew plastic nuts and either
withdraw pipework or remove
Digital Mixer to gain access to the
checkvalve cartridges and filters.
Use flat blade screwdriver to
carefully lever cartridges out.
Remove filters and clean or renew.
Refit seals, pipes and plastic nuts. Plastic nuts require hand tightening only.
Restore water supply and electrical supply. Test shower and check for leaks.
MAINTENANCE
General
Read the section “Important Safety Information” first.
Before replacing any parts ensure that the underlying cause of the malfunction has
been resolved.
If the shower is dismantled during installation or servicing then upon completion the
product must be inspected to ensure there are no leaks.
Warning! There are no user serviceable components beneath the cover of the
appliance. Only a competent tradesperson should remove the cover.
Cleaning
Many household cleaners contain abrasives and chemical substances, and should not
be used for cleaning plated or plastic fittings. These finishes should be cleaned with
a mild washing up detergent or soap solution, and then wiped dry using a soft cloth.
Checkvalve Cartridges and Filters - Removal and Installation
Hot water entering the cold supply, or vice versa, indicates that immediate attention is
necessary. This is carried out by removing and cleaning, or renewing as necessary,
the checkvalve cartridges.
Note!
Ensure for HP Mixer Valve that flow regulator is refitted in hot supply.