10
1199702-W2-H
Mira Digital Mixer Valve Pumped
Pressures
Maximum Static Pressure
100 kPa (1 bar) = 10 m max. total head
Maximum Maintained Pressure
100 kPa (1 bar) = 10 m max. total head
Minimum Maintained Pressure
1 kPa (0.01 bar) = 0.1 m min. total head
Supply Pressure Differential
Nominally Equal
Temperatures
Maximum Temperature (factory preset)
45 °C
Maximum Temperature (settable range)
38 °C - 48 °C
Minimum Temperature
Thermostatic control down to 30 °C
Full Cold also selectable
Hot Water Range
55°C - 65°C
Cold Water Range
1°C - 20°C
Temperature Stability
± 1°C at recommended supply conditions
Ambient Temperature
1°C - 40°C
Maximum Relative Humidity
95% non-condensing at 30 °C
Flow Rates and Times
Flow Rates (will vary depending on inlet
maintained pressure and spray mode)
Max @ 0.01 bar = 16 l/min
Min @ 0.01 bar = 6 l/min
Electrical
Supply Voltage
230V AC 50 Hz
Maximum Load
200 W at 230V AC