Operating fluids and maintenance
Operation and Maintenance Manual
Maintenance schedule — COP Fuel optimized
5.9.2 COP Fuel optimized — Service level 2 - Version:
2018/06-1
SL204 Cylinder head
valves
1000
2
X
Check / set valve clearance.
SL219
–B
Exhaust gas
turbocharger
7500
X
Replace the exhaust gas turbocharger rubber sleeve.
SL205 Injection
10000
X
Replace fuel lines and injectors.
SL206 Cylinder
10000
X Clean cumbastion chambers.
SL213 Exhaust gas
turbocharger
10000
X
Replace the exhaust gas turbocharger.
SL215 Water pump
10000
8
X
Replace the water pump.
SL219
–A
Coolant lines
10000
4
X
X
Check and replace coolant lines and hoses if necessary.
SL223 Battery charging
alternator
10000
X
Replace the battery charging alternator.
SL225 Viscous damper
10000
X
Replace the viscous damper.
SL209 High pressure
pump
20000
8
X
Replace the HP pump.
Tab. 28: COP Fuel optimized — Service level 2
60
© 2018 by Kohler Co. All rights reserved.
KD36V16 33521029701_1_1 en 2018-08-01