Operation and Maintenance Manual
Operating fluids and maintenance
Maintenance schedule — PRP Fuel optimized
5.7 Maintenance schedule — PRP Fuel
optimized
5.7.1 PRP Fuel optimized — Service level 1 - Version:
2018/06-1
SL100 Oil analysis
250
2
X
Take oil sample and perform oil analysis. Carry out after
500 h for category 3 and 2 lubricant.
SL121 Engine oil and oil
filter with lube oil
“Category 1”
250
2
X
Replace Diesel engine oil and oil filter insert (at least every
2 years). Perform once after 250 hours. At the latest after
one year.
V-ribbed fan belt
500
X Check belt tension.
SL121 Engine oil and oil
filter with lube oil
“Category 2”
500
2
X
Replace Diesel engine oil and oil filter insert (at least every
2 years). Perform once after 250 hours. At the latest after
one year.
SL105 Main fuel filter
1000
2
X
Replace main fuel filter.
SL106 Primary fuel filter
1000
2
Replace the primary fuel filter.
SL121 Engine oil and oil
filter with lube oil
“Category 3”
1000
2
X
Replace Diesel engine oil and oil filter insert (at least every
2 years). Perform once after 250 hours. At the latest after
one year.
SL107 Crankcase
breather
2000
2
X
Replace oil separator filter insert.
SL118 V-ribbed fan belt
2000
2
X
Replace belt.
SL108 Air filter
3000
2
X
Replace air filter main element.
SL109 V-ribbed belt for
battery charging
alternator
4000
2
X
Check state of belt drive, replace if necessary.
SL116 Coolant
(Glysantin G48)
6000
4
X
Replace coolant. For coolant formulated with Glysantin
G40, the extension up to 8000h / 6Y is possible after
analysis.
SL120 Coolant analysis
2
X Take coolant sample and perform coolant analysis.
Tab. 23: PRP Fuel optimized — Service level 1
KD36V16 33521029701_1_1 en 2018-08-01
© 2018 by Kohler Co. All rights reserved.
55