Troubleshooting (cont.)
Symptom
Probable Cause
Recommended Action
6.
Water leaking
from the
valve inlet.
A.
Arm to
control stop
seal is worn
or damaged.
•
Turn off the water supply.
•
Purge the valve.
•
Disconnect the valve from the
control stop.
•
Inspect the O-ring seal for the
control stop to inlet connection.
•
Clean any debris from area.
•
If the O-ring is cut or torn,
order a replacement.
•
Reassemble the unit, taking
care to tighten the nut onto the
control stop.
7.
An LED
signal emits
from the
sensor.
A.
The signal
repeats once
per second
when in
range of the
sensor and
the valve
activates.
•
Batteries are low.
•
Follow the directions of
″
Replace the Battery
″
section in
this guide.
B.
The signal
repeats once
per second
when in
range of the
sensor and
the valve
does not
activate.
•
Battery life has expired.
•
Follow the directions of
″
Replace the Battery
″
section in
this guide.
1108709-5-E
24
Kohler Co.