Remove the Solenoid
Close the control stop valve (refer to the
″
Control Stop Valve
Operation
″
section).
NOTE:
If the unit has not flushed since the stop valve was closed,
the inlet arm may still be pressurized. Use the manual flush button
to release pressure.
Use a 3/32
″
hex wrench to remove the setscrew from the cap.
Remove the cap.
Disconnect the DC sensor connector from the solenoid connector
by pulling the two connectors apart.
Temporarily store the cap and DC sensor assembly in a safe
place.
Use an adjustable wrench to remove the solenoid assembly from
the valve body by unscrewing counterclockwise until the solenoid
is free.
Valve Body
Diaphragm
Cap
Setscrew
O-Ring
Piston
Retaining Nut
Pin
Spring
Piston Cover
Solenoid
Connector
DC Sensor
Connector
Solenoid
Assembly