Kohler GM62345 Installation Instructions Manual Download Page 6

6

TT-1445 7/16

10/12RESV(L)

1.

Before working on the generator set or connected
equipment, disable the generator set as follows:

a.

Press the OFF button on the generator set controller.

b.

Disconnect the power to the battery charger.

c.

Remove the battery cables, negative (--) lead first.

2. Rotate the air cleaner cover levers outward to

unlock cover; remove the air cleaner cover.

3. Remove and discard the old air cleaner element.

4. Install the paper element onto the air cleaner base.

Make sure the element is flat and properly seated.

5. Position the air cleaner cover with levers outward

over air cleaner; turn levers inward to lock.

6. Reconnect the battery cable, negative (--) lead last.

tp6515

1. Air cleaner cover lever

2. Air cleaner element

3. Base

4. Blower housing

5. Air cleaner cover

2

3

1

4

5

Figure 7

Air Cleaner; 10/12RESV(L)

17/18RES(L), 20RES(A)(AL)(B)(C)(CL)(D)(L)

1.

Before working on the generator set or connected
equipment, disable the generator set as follows:

a.

Press the OFF button on the generator set controller.

b.

Disconnect the power to the battery charger.

c.

Remove the battery cables, negative (--) lead first.

2. Loosen the two cover retaining knobs and remove

the cover.

3. Rotate the air filter latch counterclockwise to

unlock, then remove the paper element.

4. Install the paper element onto the air cleaner base.

Make sure the element is flat and properly seated.

Rotate the latch clockwise, over the molded lip on

the element.

5. Install the air cleaner cover and secure with the two

retaining knobs.

6. Reconnect the battery cable, negative (--) lead last.

1

tp6515

1. Knobs (qty.2)

2. Cover

3. Paper element

4. Base

3

2

4

Figure 8

Air Cleaner; 17/18RES(L),

20RES(A)(AL)(B)(C)(CL)(D)(L)

Summary of Contents for GM62345

Page 1: ...r sets listed in Figure 1 Read the entire installation procedure before beginning installation Perform the steps in the order shown Generator Set Service Kit Number Sales Kit Number 8RESV L GM90365 GM...

Page 2: ...ner A sudden backfire can cause severe injury or death Do not operate the generator set with the air cleaner removed Hot engine oil Can cause severe injury or death Avoid skin contact with hot oil Do...

Page 3: ...a drain pan The tube will reduce the potential for spilled oil c Open the oil drain valve on the engine d Remove the dipstick and oil fill cap Allow time for the engine oil to drain completely e Clos...

Page 4: ...eler gauge See Figure 4 Adjust the gap by carefully bending the ground electrode See Figure 3 5 For easy removal apply a light coating of anti seize lubricantto the sparkplug threads Wipe away any exc...

Page 5: ...ct the battery cable negative lead last 1 2 3 4 5 6 7 586536 1 Cover knob 2 Air cleaner cover 3 Element cover nut 4 Element cover 5 Foam precleaner 6 Air cleaner element 7 Air cleaner base Figure 5 Ai...

Page 6: ...t 3 Base 4 Blower housing 5 Air cleaner cover 2 3 1 4 5 Figure 7 Air Cleaner 10 12RESV L 17 18RES L 20RES A AL B C CL D L 1 Before working on the generator set or connected equipment disable the gener...

Page 7: ...tap 1 8 27 NPT 5 Primary element 6 Dust ejector 1 2 3 5 6 4 Figure 9 Air Cleaner 15RES A R E YG and 30RES A R E YG 24RCL 30RCL 38RCLB 48RCLA and 60RCL 1 Before working on the generator set or connect...

Page 8: ...s negative lead first 2 Remove the wing nut and remove the air cleaner retaining plate 3 Remove and discard the old air cleaner element 4 Install the new element 5 Wipe the cover and housing with a cl...

Reviews: