Kohler GM62345 Installation Instructions Manual Download Page 5

TT-1445 7/16

5

Air Cleaner Element and Precleaner

6VSG, 8.5RES, 12RES(L), 14RES(A)(AL)(L)

1.

Before working on the generator set or connected
equipment, disable the generator set as follows:

a.

Press the OFF button on the generator set controller.

b.

Disconnect the power to the battery charger.

c.

Remove the battery cables, negative (--) lead first.

2. Loosen the cover retaining knob and remove the

cover.

3. Remove and discard the old air cleaner element

and precleaner (if equipped).

4. Install the precleaner over the new air cleaner

element.

5. Install the paper element, precleaner, element

cover, element cover nut, and the air cleaner cover.

6. Secure the cover with the cover retaining knob.

7. Reconnect the battery cable, negative (--) lead last.

1

2

3

4

5

6

7

586536

1. Cover knob

2. Air cleaner cover

3. Element cover nut

4. Element cover

5. Foam precleaner

6. Air cleaner element

7. Air cleaner base

Figure 5

Air Cleaner; 6VSG, 8.5RES, 12RES(L),

14RES(A)(AL)(L)

8RESV(L)

1.

Before working on the generator set or connected
equipment, disable the generator set as follows:

a.

Press the OFF button on the generator set controller.

b.

Disconnect the power to the battery charger.

c.

Remove the battery cables, negative (--) lead first.

2. Loosen the cover retaining knobs and remove the

cover.

3. Remove and discard the old air cleaner element.

4. Install the paper element and the air cleaner cover.

Secure the cover with the cover retaining knobs.

5. Reconnect the battery cable, negative (--) lead last.

1. Air cleaner base

2. Air cleaner element

3. Element cover

4. Air cleaner knob

1

2

4

586536

3

Figure 6

Air Cleaner; 8RESV(L)

Summary of Contents for GM62345

Page 1: ...r sets listed in Figure 1 Read the entire installation procedure before beginning installation Perform the steps in the order shown Generator Set Service Kit Number Sales Kit Number 8RESV L GM90365 GM...

Page 2: ...ner A sudden backfire can cause severe injury or death Do not operate the generator set with the air cleaner removed Hot engine oil Can cause severe injury or death Avoid skin contact with hot oil Do...

Page 3: ...a drain pan The tube will reduce the potential for spilled oil c Open the oil drain valve on the engine d Remove the dipstick and oil fill cap Allow time for the engine oil to drain completely e Clos...

Page 4: ...eler gauge See Figure 4 Adjust the gap by carefully bending the ground electrode See Figure 3 5 For easy removal apply a light coating of anti seize lubricantto the sparkplug threads Wipe away any exc...

Page 5: ...ct the battery cable negative lead last 1 2 3 4 5 6 7 586536 1 Cover knob 2 Air cleaner cover 3 Element cover nut 4 Element cover 5 Foam precleaner 6 Air cleaner element 7 Air cleaner base Figure 5 Ai...

Page 6: ...t 3 Base 4 Blower housing 5 Air cleaner cover 2 3 1 4 5 Figure 7 Air Cleaner 10 12RESV L 17 18RES L 20RES A AL B C CL D L 1 Before working on the generator set or connected equipment disable the gener...

Page 7: ...tap 1 8 27 NPT 5 Primary element 6 Dust ejector 1 2 3 5 6 4 Figure 9 Air Cleaner 15RES A R E YG and 30RES A R E YG 24RCL 30RCL 38RCLB 48RCLA and 60RCL 1 Before working on the generator set or connect...

Page 8: ...s negative lead first 2 Remove the wing nut and remove the air cleaner retaining plate 3 Remove and discard the old air cleaner element 4 Install the new element 5 Wipe the cover and housing with a cl...

Reviews: