background image

6

112363–2–

AA

 (0793)

Kohler Co., Kohler, WI

CHECK FOR LEAKS

Turn on shut-off valve and check for leaks. If connections
are squarely assembled, a slight re-tightening of the nuts
will stop any leaks. Check all connections for leaks for
several days. The nuts under the bolt caps may also re-
quire re-tightening.

Fig. #10

TO ADJUST WATER LEVEL

To obtain the correct water level in the tank, adjust the
Tank Water Level Screw, by turning counterclockwise to
raise the water level, or clockwise to lower the water level.

Fig. #11

Raise

Lower

Tank Water
Level Screw

Summary of Contents for FLEUR WATERGUARD K-3417 AA Series

Page 1: ...e from rim to water surface is 6 3 4 2 passageway For roughing in and overall dimensions see Fig 2 Fixture dimensions are nominal and conform to tol erances by ANSI standards A112 19 2 PRODUCT REQUIRE...

Page 2: ...ge with a putty knife Remove old T bolts the T shaped bolts in the closet flange and discard CAUTION Risk of hazardous gases If new toilet is not installed immediately temporarily stuff a rag in the c...

Page 3: ...Firmly place gasket on toilet outlet If using a gasket with integral plastic sleeve position gasket with sleeve facing away from toilet If desired place a 1 4 thick bead of toilet setting com pound ar...

Page 4: ...nd remove the tank lid Remove bags located in the tank Assemble tank gasket into place and lower the tank onto the base carefully aligning the holes on tank and base Insert rubber washers washers and...

Page 5: ...compression nut and ferrule onto tubing Insert tubing into shut off valve and supply shank positioning seal washer supplied or compression washer not supplied as shown Hand tighten coupling nut and t...

Page 6: ...will stop any leaks Check all connections for leaks for several days The nuts under the bolt caps may also re quire re tightening Fig 10 TO ADJUST WATER LEVEL To obtain the correct water level in the...

Page 7: ...ace plunger 3 Valve does not shut off and water is flowing A Defective plunger A Replace plunger and water is flowing into the overflow NOTE After tank is filled to water level line turn off sup B Wat...

Page 8: ...either your contractor or Kohler Co distributor please write us directly at Kohler Co Attn Consumer Affairs Department Kohler WI 53044 U S A FOURTH Include all pertinent information regarding your cla...

Reviews: