background image

1

PHII 

        THE FOLLOWING ARE CAUTIONARY STATEMENTS THAT MUST BE READ AND FOLLOWED  

 

    

 

 

DURING BOTH INSTALLATION AND OPERATION 

 

 

 

               

WARNING:

 

Raritan Engineering Company, Inc. recommends that a qualified  person or electrician    

 

 

 

in the case of  P104E**,  install this product.  Equipment damage, injury to personnel or death    

 

 

could result from improper installation.  Raritan Engineering Company,  Inc.  accepts no responsibility  

 

 

or liability for damage to equipment, or injury or death to personnel,  that may result from improper  

 

 

installation oroperation of this product.

WARNING:

 

Hazard of Flooding

 

Any installation made below the waterline must have vented loops positioned 

properly and all hose connections should be double-clamped.  Both intake and discharge seacocks 

should always be in the closed position when the toilet is not in use.  Failure to do so may result in 

flooding, property damage and loss of life. 

 

 

 

 

 

 

 

WARNING:

 

DO NOT

 install in an area requiring Ignition Protected Devices.

  

DO NOT 

operate P104E** series toilets with handle in place, serious bodily injury may occur.

The PHII is a manually operated double action piston 

toilet. The PHII can be converted to its electrical 

counterpart by adding an electrical conversion kit 

part# P104E**

All models are suitable for use in conjunction with our  

US Coast Guard Certified Type I flow-thru Marine 

Sanitation Devices (MSD), Raritan’s Electroscan® 

and Purasan®. 

1-856-825-4900

www.raritaneng.com

Model and Serial # :

 INSTALLATION AND MAINTENANCE INSTRUCTIONS

** Specify voltage 12 or 24 VDC

Link to online 

Warranty 

Registration

L584v0222jlc

Summary of Contents for PHII

Page 1: ...should be double clamped Both intake and discharge seacocks should always be in the closed position when the toilet is not in use Failure to do so may result in flooding property damage and loss of l...

Page 2: ...ances paper towels feminine hygiene products filter cigarettes etc must not be thrown into the toilet as they will cause damage Always shut off seacock s before leaving the boat unattended Cleaning In...

Page 3: ...harged from toilet 7 Antifreeze should remain in the toilet until recommissioning This will protect both intake and discharge sides of the pump Pouring antifreeze into the bowl will only protect the d...

Page 4: ...t will be located Make sure there is room to route hoses Make sure seat will open properly 3 Mark location of toilet base mounting holes on mounting surface 4 Drill holes for toilet mounting bolts scr...

Page 5: ...ge outlet with a vented loop This will enable the toilet to discharge more efficiently and will help to prevent backflow 2 An In Line Strainer 163000 is recommended This will help minimize odors and h...

Page 6: ...S S 8 1228CW Flapper Valve Assembly 1 2 Holes 1232MS Piston O Ring 1234 Bowl Gasket 1236E Bowl Elbow 1248W Base w Plug 1249 Base Plug not shown 221361 Washer Inlet Adapter C253 Joker Valve CH42 Hose I...

Page 7: ...ssy 1213C 1248W 1232MS 1124 LWS 1209BW 1213D 1226B 1210B 1201 1204B 1115 1202 CH42 F005 1211PL 1213A 1213W Seal Assy on units built before June 1992 LWS 1201 1210 1214 1214B 1214A 1210A 1236E 221361 C...

Page 8: ...n Post 1992 PHII and PH Superflush Powerflush 4 1226C Housing Spacer Washer not necessary if 1248W base older PH PHII 39 1 1228CW Flapper Valve Assembly See Correct Orientation ALL 37 1 1232MS Piston...

Page 9: ...sping the 1209BW handle and gently lifting upwards the entire assembly down to part 1203BW can be removed Clean out any debris in this area Replace gasket part 1202 if necessary and apply a small amou...

Page 10: ...as necessary Scored pump housing or worn piston O ring Inspect inside of housing replace O ring and housing as necessary Intake line or strainer clogged Clean line and strainer Water rises in bowl Ven...

Page 11: ...tbreakerin OFF position before proceeding 1 Remove arm bolt and nut 1115 and 1115A from the top of the connecting rod 1134 2 Displace connecting rod 1134 from track 3 Insert the handle 1208W and cotte...

Page 12: ...t This warranty also does not cover damages to equipment caused by fire flood external water excessive corrosion or Act of God 3 ANY EXPRESS WARRANTY NOT PROVIDED HEREIN AND ANY REMEDY FOR BREACH OF C...