4
116897-2-
AB
Kohler Co., Kohler, WI
D. ADJUST DOOR ASSEMBLY AND
TIGHTEN SCREWS
Measure diagonally across each side of the door
assembly and adjust, if necessary, for equal measure-
ments on each side.
Refer to Install Fixed Panels on page 2 for location of
patch screws.
Tighten the fixed panel patch screws with the hex wrench
provided and insert the screw covers over the screw
heads. Lift bottom of moving panel and tilt up and away
from fixed panel to gain access to lower inside patch
screws.
Now tighten the twelve #6-20 x 1” panhead screws that
attach the top and bottom tracks to the wall
jamb/expander jamb assembly. Refer to Step C.
Fixed Panel
Patch
Fixed
Panel Patch
E. ENGAGE CATCHES
Place the catch into the bottom track recess with the catch
and turngrip lever disengaged.
Catch in the
Disengaged Position
Turngrip Lever in the
Disengaged Position
Catch Stops
Turngrip Lever
Move the turngrip lever to the position shown at right until
the catch stops.
Turngrip Lever in the
Engaged Position
Move the lever back one step as shown to allow for
sufficient operating clearance.
Move Lever Back
One Step
Repeat for the remaining three catches.
Bottom
Track
Catch in the
Engaged Position
Stand door assembly upright.