11.9
Section 11
Reassembly
11
4. Install the breather filter into the cavity in the
crankcase. See Figure 11-24.
Figure 11-24. Installing Breather Filter.
5. Carefully install the breather cover gasket and
breather cover onto the crankcase. See Figure
11-25.
1
3
2
4
Figure 11-25. Installing and Torquing Breather
Cover/Screws.
6. Install and torque the four breather cover hex.
flange screws to 7.3 N·m (65 in. lb.) in the
sequence shown in Figure 11-26.
Figure 11-26. Breather Cover Fastener Torque
Sequence.
7. Install the pipe plug or Oil Sentry™ switch (as
equipped), into the tapped breather port if removed
earlier. Apply pipe sealant with Teflon
®
(Loctite
®
59241 or equivalent) to the threads. Torque to
6.8 N·m (60 in. lb.).
Figure 11-27. Oil Sentry™ Switch Installed.
8. If the vacuum fitting was removed from the
crankcase (vacuum fuel pump), apply pipe
sealant with Teflon
®
(Loctite
®
59241 or
equivalent) to the threads of the fitting and install.
With the crankcase upright, the fitting must point
to the 1:30 position. See Figure 11-28.
Not For Resale