background image

Display cycle setting (SET8)

Use this setting to configure the display cycle.

Adjustment setting (SET9)

Configures the adjustment setting.

Press 

Press 

1 second later

Return to

Use 

 or 

 key to select 

the smoothing setting 

from the list below.

<Smoothing setting>

: No smoothing (factory setting)
: 4 times
: 8 times
: 16 times

* Usually, it is not necessary to configure SETA - SETC.

Error Indicators

Indicator

Meaning 

Required action

The sensor head of the 

selected channel is not 

connected or has been 

disconnected.

In the case of disconnection, 

turn off power and replace the 

sensor head.

Invalid scaling setting.

Reconfigure the scaling setting 

so it satisfies the required 

scaling conditions.

Over voltage being applied to 

sensor input.

After correcting for the source 

of the problem, hold down the 

MODE key for more than one 

second.

Over voltage being applied to 

switch output.

n

(n: applicable channel)

*  For other information, detailed specifications, and precautions, see the product 

catalog.

*  For inquiries about the product, contact your nearest Koganei sales office or the 

Overseas Group noted below.

OVERSEAS GROUP 

3-11-28, Midori-cho, Koganei City, Tokyo 184-8533, Japan 

Tel: 042-383-7271 Fax: 042-383-7276

Use 

 or 

 key to select 

the display refresh cycle 

setting from the list below.

<Display cycle setting>

: 100 ms (factory setting)
:  250 ms
:  500 ms
:  1000 ms

Press 

Press 

1 second later

Return to

Switch output inversion setting (SET4)

This setting can be used to invert the switch output of each channel.

Setting CH is displayed

CH1 to 4: Select the setting CH

Use 

 or 

 key to select 

the setting CH.

Reverse the setting of the 

switch output. The indicator 

corresponding to the setting 

CH blinks.

Use 

 or 

 key to select the switch 

output reverse mode from the list below.

<Switch output reverse mode>

: No reverse (Factory setting)
: Reverse

Press 

Press 

Press 

Press 

Press 

Press 

Press 

Press 

Press 

Press 

Press 

Press 

Press 

Press 

Press 

Press 

Press 

Press 

The set value is displayed for 1 second.

1 second later

1 second later

1 second later

1 second later

1 second later

Return to

Return to

Sensor head LED indicator light setting SET5)

Configure the sensor head LED indicator display range setting
The sensor head LED indicator turns on within the effective measuring range with the factory setting.

Configure the upper limit 

of the sensor head LED 

indicator display range.

Use 

 or 

 key to 

change the setting 

values.

Input value: 0 to 1000

Configure the lower limit 

of the sensor head LED 

indicator display range.

Use 

 or 

 key to 

change the setting 

values.

Input value: 0 to 1000

Scaling setting (SET6)

Configure the display scaling.
No change after scaling for the analog output (1-5V).

※※※

※※※

※※※

※※※

SCAL: Scaling setting

INIT: Scaling initialization

Configure scaling point 1.

Move the cylinder to scaling 

point 1 (A1)

Move the cylinder to the display 

value (B1) of scaling point 1.

Use 

 or 

 key to 

change the setting 

values.

Input value: 0 to 1000

Configure scaling point 2.

Move the cylinder to scaling 

point 2 (A2)

Move the cylinder to the 

display value (B2) of scaling 

point 2.

Use 

 or 

 key to 

change the setting 

values.

Input value: 0 to 1000

Return to 

Return to

Return to

A1-A2

/

B1-B2

|>

=1

The scaling setting is initialized and 

a value of 0 to 1000 is displayed.

or

Backlight display setting (SET7)

Use this setting to configure backlight color settings.

Use 

 or 

 key to select 

the backlight color setting 

from the list below.

[Backlight color setting]

: Backlight OFF

: When switch output OFF: Green When switch output ON: Red (factory setting)
: When switch output OFF: Red When switch output ON: Green
: Always green
: Always red

Summary of Contents for ZL2

Page 1: ...essed into the body Connection is complete when the cover is even with the connector body 6 Double check to make sure that wiring is correct 654321 Sensor head RedBlackWhite Brown 654321 Sensor head Yellow Blue Attaching and detaching of the sensor head and power switch cables To attach the sensor head and the power switch cables position the lock levers as shown in the illustration above and then...

Page 2: ...ead V brown lead Tr1 Tr2 Tr3 Tr4 Tr5 ZD5 ZD4 ZD3 ZD2 ZD1 3 5 1 6 7 8 4 2 STABI black lead Vcc brown lead OUT1 white lead OUT2 red lead OUT3 green lead OUT4 yellow lead GND blue lead Analog output gray lead Signal D Power supply reverse polarity protection diode ZD1 ZD5 Surge voltage absorption zener diode Tr1 Tr5 NPN output transistors Load Load Load Load Load Main circuit Sensor section Main circ...

Page 3: ...corresponding to the setting CH turns on Backlight color green Backlight color green Use or key to change the setting values Input value 0 to 1000 Factory setting 400 1 second later Press Press Press ALL when selected moves to the next CH setting If not completed to CH4 1P 1 Point teaching threshold setting 2P 2 Point teaching threshold setting Set the threshold Use or key to change the tolerance ...

Page 4: ...or key to select the switch output reverse mode from the list below Switch output reverse mode No reverse Factory setting Reverse Press Press Press Press Press Press Press Press Press Press Press Press Press Press Press Press Press Press The set value is displayed for 1 second 1 second later 1 second later 1 second later 1 second later 1 second later Return to Return to Sensor head LED indicator l...

Reviews: