Inner Circuit Diagrams
Setting
Nomenclature and functions
Output mode
No.
Name
①
Display
Shows effective measuring range %, setting details, error indicators.
②
Switch output indicators
Light when switch output is ON (CH1 to CH4).
③
UP key (
)
Use to increase a setting value.
④
DOWN key (
)
Use to decrease a setting value.
⑤
MODE key (
)
Use when configuring settings.
⑤
②
④
①
③
ZL2
1
2
3
4
SW.OUT
■
Window comparator mode
Display
OUT1
LCD display
1000
600
400
0F
Response
differential (fixed)
t
Response
differential (fixed)
)
)
Effective
setting range
signal
(STABI)
The ON range of each output can be set within the effective
measuring range (sensor head ON range).
Response differential is fixed (2 digits)
When the controller setting and sensor heat setting positions are as shown below.
OUT1 Threshold value setting Upper limit: 600 Lower limit: 400
Display when hand is full open: 900
ZL2
ZL2
ZL2
ZL2
Hand full open Holding workpiece Hand fully closed Hand full open
■
Hysteresis mode
Display
OUT1
LCD display
CAUTION: When the effective measuring range signal is OFF
(outside the measuring range), OUT also becomes OFF.
1000
200
400
0F
t
Hand full open Holding workpiece Hand fully closed Hand full open
Effective
setting range
signal
(
STABI
)
The ON position and OFF position each output can be set within the
effective measuring range (sensor head ON range).
When the controller setting and sensor heat setting positions are as shown below.
OUT1 Threshold value setting Upper limit: 400 Lower limit: 200
Display when hand is full open: 900
ZL2
ZL2
ZL2
ZL2
CAUTION
1. Incorrect wiring of the sensor head or power/switch cable will damage both the controller and the sensor head. Be sure to double-
check and make sure that wiring is correct before supplying power.
2. Parameters that are set are recorded into flash memory and retained there. Note that flash memory has a limited service life. The
guaranteed number of rewrites is 10,000.
■
Getting ready to configure settings
・
Connect the sensor head and power/switch cable to the controller. (Refer to "Attaching and detaching of the sensor head and power/
switch cables" on page
❷
).
■
Configuring settings
24 VDC
±10
%
+
−
D
Linear magneticsensor controller
Sensor head
Power/switch cable
Note: Note that extending the cable can cause a drop in voltage due to cable resistance.
1
4
2
3
5
6
OV (blue lead)
C_IN (yellow lead)
B_IN (black lead)
A_IN (white lead)
LED (red lead)
+V (brown lead)
Tr
1
Tr
2
Tr
3
Tr
4
Tr
5
Z
D5
Z
D4
Z
D3
Z
D2
Z
D1
3
5
1
6
7
8
4
2
STABI (black lead)
+Vcc (brown lead)
OUT1 (white lead)
OUT2 (red lead)
OUT3 (green lead)
OUT4 (yellow lead)
GND (blue lead)
Analog output (gray lead)
Signal D
: Power supply reverse-polarity protection diode
Z
D1
~ Z
D5
: Surge voltage absorption zener diode
Tr
1
~Tr
5
: NPN output transistors
Load
Load
Load
Load
Load
Main circuit
Sensor section
Main circuit
YES
Purchase the set of the
controller and the sensor head
Install direction setting
(SET0)
Equipped cylinder setting
(SET2)
Threshold and switch output mode
setting (SET1&SET3)
Additional settings as needed
(SET4~9)
Start
detection
Sensor head
parameter setting
(SETd)
NO
First specify the cylinder model that is equipped (SET2), and then configure the other settings (as shown below).
You also can use the procedure below to modify settings.
General flow
Note 1: Always be sure to
configure the
equipped cylinder
model setting. Failure
to do so creates the
risk of malfunction.
2: Note that initialization
(SETA, SETB)
initializes all settings,
so any settings you
have configured are
lost.
Note 2
Note 1
increases
the value,
decreases
it.
Detection mode
Detection
mode is
Indicated
when LCD
shows OF or
OFF.
Button operation
Long press
Install direction
setting
Configures the install
direction
Sn-0
Sets the output range of
each channel.
HI:600
LO:400
Selects the model of the
equipped cylinder.
18
Selects the output mode
of each channel.
CO
Can be used to invert the
switch output of each channel.
S-0
Changes the display position of
the sensor head LED indicator.
HI:600
LO:400
Configures the scaling
setting.
OFS:0
FS:1000
Configures the display
panel setting.
bL-1
Configures the LCD
display cycle setting.
dt-1
Adjusts the switch output
response time of each channel.
FL-0
Performs Initialization 1.
Performs Initialization 2
(display, output check).
Adjusts the maximum output
voltage of analog output.
Configures the sensor
head parameters.
Exits the settings and returns
to the detection mode
Setting items
LCD display
Description
Initial default
Switch output
threshold setting
Equipped cylinder
model setting
Switch output
mode setting
Switch output
reverse setting
Sensor head LED indicator
display range setting
Scaling setting
Display backlight
color setting
Display refresh
cycle setting
Adjustment setting
Initialization (except SETC&SETd)
[Press
△▽□
at the same time]
Initializes all settings
[Press
△▽□
at the same time]
Analog output maximum
voltage setting
Sensor head
parameter setting
Exit setting
Press
Detailed
configuration
of each
setting is
supported.